1

00:00:03,072  -->  00:00:05,632
Hello guys my name is caner

2

00:00:07,168  -->  00:00:09,216
with this chapter

3

00:00:09,728  -->  00:00:11,008
chapter 16

4

00:00:12,544  -->  00:00:17,664
now you will learn how do we use the simulation simosim

5

00:00:17,920  -->  00:00:19,712
simotion scout

6

00:00:21,760  -->  00:00:27,904
So first of all when do you install your simotion with setup dvds

7

00:00:29,696  -->  00:00:30,976
You have to select

8

00:00:33,280  -->  00:00:34,304
Option

9

00:00:35,840  -->  00:00:41,984
And after that it's really easy to use and you need to check your ethernet adapters

10

00:00:44,800  -->  00:00:50,944
at your control panel and network connections i use Windows 10 for instance you'll see

11

00:00:51,200  -->  00:00:56,320
My internet and wireless network adapters

12

00:00:58,112  -->  00:01:02,208
This one is siemens simosim must be enabled

13

00:01:02,464  -->  00:01:05,024
As virtual internet adapter

14

00:01:05,280  -->  00:01:08,608
And you see here the Internet Protocol

15

00:01:08,864  -->  00:01:11,424
My IP address is automode

16

00:01:14,752  -->  00:01:16,800
And after that

17

00:01:20,640  -->  00:01:23,712
For example I have switch simotion scout

18

00:01:23,968  -->  00:01:26,528
To my first project

19

00:01:27,296  -->  00:01:28,832
3-4 different

20

00:01:29,088  -->  00:01:31,904
CPUs with different firmwares

21

00:01:32,672  -->  00:01:34,976
The first one

22

00:01:35,232  -->  00:01:36,512
D425-2

23

00:01:37,536  -->  00:01:43,680
I click the properties and its version is 5.2

24

00:01:47,520  -->  00:01:52,128
Just take your attention here when I click the simotion CPU

25

00:01:52,384  -->  00:01:53,664
There's an icon

26

00:01:54,432  -->  00:02:00,064
in green or light green color and it's for start the simosim

27

00:02:03,136  -->  00:02:05,440
And for older versions

28

00:02:05,952  -->  00:02:10,816
For example 4.5 you see here is not active

29

00:02:11,840  -->  00:02:13,632
It's not possible to use

30

00:02:13,888  -->  00:02:20,032
simulation simosim with older firmware versions unfortunately

31

00:02:20,544  -->  00:02:24,640
It's active in 5.1 and 5.3

32

00:02:26,944  -->  00:02:33,088
CPU on the left side at my project tree than i enter or click here

33

00:02:33,344  -->  00:02:36,160
start simosim

34

00:02:38,720  -->  00:02:44,864
You may read information for simulation that are something necessary to do or what

35

00:02:45,120  -->  00:02:46,400
 by the system

36

00:02:48,960  -->  00:02:51,008
when i Accept the setting

37

00:02:51,264  -->  00:02:54,848
It's real change my access point settings

38

00:02:55,104  -->  00:02:58,944
Interface settings for going online

39

00:02:59,968  -->  00:03:02,016
on my PC with simulation

40

00:03:02,272  -->  00:03:08,416
So that means it's not possible to go online with the real system at the meantime

41

00:03:10,208  -->  00:03:11,744
after simulation

42

00:03:12,000  -->  00:03:14,816
I have to switch back to

43

00:03:15,072  -->  00:03:17,888
You're my oldest settings by myself

44

00:03:18,400  -->  00:03:21,216
So I agreed to accept settings

45

00:03:22,240  -->  00:03:25,312
Click to start simulation button

46

00:03:26,848  -->  00:03:28,384
So there is a pop up

47

00:03:29,408  -->  00:03:30,944
Always stays at top

48

00:03:34,272  -->  00:03:36,320
And I see here

49

00:03:37,856  -->  00:03:40,928
The faceplate of the simulation

50

00:03:41,184  -->  00:03:46,304
SF run stop diagnostic leds

51

00:03:46,816  -->  00:03:51,680
It's possible to stimulates and several functions like memory reset

52

00:03:51,936  -->  00:03:54,752
You see here the seven segment display

53

00:03:55,264  -->  00:03:58,080
and reset button important diagnostic files

54

00:03:58,336  -->  00:04:01,664
It also supports the web server function

55

00:04:02,176  -->  00:04:03,200
You just

56

00:04:03,456  -->  00:04:09,088
You're the simotion scout simotion web server

57

00:04:13,440  -->  00:04:16,256
It consists of several things

58

00:04:18,047  -->  00:04:20,863
If you click the save cards

59

00:04:21,119  -->  00:04:22,143
Then CF card

60

00:04:22,399  -->  00:04:24,191
you see here some folders

61

00:04:24,959  -->  00:04:29,567
Just like in real system so you can manage

62

00:04:29,823  -->  00:04:32,895
and test your program it's also possible

63

00:04:33,919  -->  00:04:38,783
After I start the simulation you see here

64

00:04:39,039  -->  00:04:43,135
In the status bars it says simulation mode is active

65

00:04:44,159  -->  00:04:45,439
I'm just select

66

00:04:45,695  -->  00:04:47,487
CPU right click

67

00:04:47,743  -->  00:04:49,791
to connect Target device

68

00:04:50,303  -->  00:04:52,863
Or another way I will

69

00:04:53,375  -->  00:04:57,471
Go in Target system and select Target devices

70

00:04:58,239  -->  00:05:00,799
You'll see here the possible

71

00:05:01,055  -->  00:05:02,591
Connections

72

00:05:05,663  -->  00:05:11,807
Because I choose this one the other options for other CPU

73

00:05:12,063  -->  00:05:14,623
Keep you up online interface

74

00:05:14,879  -->  00:05:16,415
Is disabled

75

00:05:16,671  -->  00:05:18,975
Just for your note

76

00:05:20,767  -->  00:05:23,583
I could connector target system

77

00:05:25,119  -->  00:05:26,143
and

78

00:05:26,399  -->  00:05:30,495
My virtual adapter for simulation is working at the backgrounds

79

00:05:30,751  -->  00:05:33,055
i am Using Scout just

80

00:05:33,567  -->  00:05:39,711
I'm working with the real CPU so you'll see here the differences between

81

00:05:39,967  -->  00:05:42,271
Online and offline partners

82

00:05:45,599  -->  00:05:51,743
And right now it's not possible to simulate the sinamics CUs for drive side

83

00:05:52,255  -->  00:05:56,607
Maybe in the future siemens will release

84

00:05:57,119  -->  00:05:58,399
This feature

85

00:06:00,959  -->  00:06:01,983
Next time

86

00:06:04,287  -->  00:06:05,823
On the other hand

87

00:06:06,079  -->  00:06:11,199
If you are using technology objects like axis positioning axis

88

00:06:11,711  -->  00:06:17,855
It's possible to execute your motion control comments everything's working

89

00:06:18,623  -->  00:06:21,183
Properly in virtual world

90

00:06:23,231  -->  00:06:29,119
so We will examine and do some exercises

91

00:06:30,399  -->  00:06:31,935
in next chapters So far so good

92

00:06:34,239  -->  00:06:36,543
Is possible to download the system

93

00:06:37,055  -->  00:06:39,359
You'll see your options

94

00:06:41,151  -->  00:06:46,271
and you see here to CPU goes to stop mode how do I download

95

00:06:46,783  -->  00:06:51,903
The information messages and the warnings are the same as the real system

96

00:06:52,415  -->  00:06:55,487
And simulation Works faster than the

97

00:06:55,743  -->  00:06:58,047
D425 CPU

98

00:06:58,559  -->  00:06:59,583
For example

99

00:07:00,863  -->  00:07:07,007
Actually I think it depends on the computer and CPU power and working frequency

100

00:07:09,823  -->  00:07:15,967
My project is downloaded and he's asking do you want to switch CPU back to run

101

00:07:17,247  -->  00:07:18,527
i click yes

102

00:07:19,039  -->  00:07:21,855
You'll see here the CPU set to run mode

103

00:07:22,879  -->  00:07:26,463
I can here use the functionality for set the Run

104

00:07:27,231  -->  00:07:28,511
Stop also

105

00:07:29,791  -->  00:07:31,839
And after you finish

106

00:07:32,095  -->  00:07:33,631
work with simulation

107

00:07:33,887  -->  00:07:35,423
You just go offline

108

00:07:35,935  -->  00:07:36,703
and

109

00:07:40,031  -->  00:07:43,359
Close the simulation I say yes

110

00:07:45,407  -->  00:07:51,551
then you want to work at in real system you select here in Project deselector simulation myode

111

00:07:54,111  -->  00:07:56,159
So it's not dactivated

112

00:07:57,183  -->  00:07:59,231
You can easily

113

00:07:59,999  -->  00:08:04,351
Set up your target devices here and access point

114

00:08:05,119  -->  00:08:06,399
Step 7 online

115

00:08:06,911  -->  00:08:08,191
For instance

116

00:08:09,471  -->  00:08:13,055
That you are able to go online with the real Hardware

117

00:08:15,615  -->  00:08:17,407
see you at Next chapters...