1

00:00:00,256  -->  00:00:02,816
Hello collegues

2

00:00:03,328  -->  00:00:06,656
Our current capter is 17

3

00:00:07,168  -->  00:00:09,984
We will learn about

4

00:00:10,496  -->  00:00:13,568
TIA portal integration

5

00:00:13,824  -->  00:00:19,968
Device proxy option for using Comfort HMI panels

6

00:00:21,248  -->  00:00:25,856
When We are programming siMotion in classical world

7

00:00:27,904  -->  00:00:33,280
So we have our example project here

8

00:00:34,048  -->  00:00:39,680
It's saved and compiled without any errors

9

00:00:41,216  -->  00:00:45,568
Okay consistency check is successful

10

00:00:46,080  -->  00:00:52,224
I will start a new project needs tia portal version 15.1

11

00:00:54,016  -->  00:00:55,808
Service Pack 1

12

00:01:00,928  -->  00:01:07,072
So sometimes it's necessary to use the classical to use

13

00:01:07,328  -->  00:01:11,168
classical simotion scout to program your PLC

14

00:01:12,192  -->  00:01:18,336
Maybe because of the maintenance team have the old license

15

00:01:18,592  -->  00:01:22,432
And don't want to upgrade your software for instance

16

00:01:24,224  -->  00:01:30,368
By the way there are some advantages Still In classical scout when do you compare with

17

00:01:30,624  -->  00:01:36,768
TIA scout option right now actually I prefer to go with the classical

18

00:01:37,024  -->  00:01:40,864
Scouts for new projects

19

00:01:41,632  -->  00:01:47,776
You see here the portal view I'm going to create a new project

20

00:01:48,032  -->  00:01:51,360
First I select my folder to store

21

00:01:51,616  -->  00:01:54,944
The project files

22

00:02:01,344  -->  00:02:06,720
So I said it here

23

00:02:09,792  -->  00:02:13,120
simotion scout system and programming folder

24

00:02:15,936  -->  00:02:22,080
Okay let's see a device proxy

25

00:02:22,336  -->  00:02:25,408
version 15.1

26

00:02:25,664  -->  00:02:30,784
D425-2 from the

27

00:02:31,552  -->  00:02:34,368
5.2

28

00:02:37,184  -->  00:02:41,280
Okay just takes a few seconds

29

00:02:58,176  -->  00:03:02,016
Okay let's switch to project View

30

00:03:03,808  -->  00:03:08,928
And add a new device

31

00:03:10,976  -->  00:03:15,072
We will use the device proxy

32

00:03:23,776  -->  00:03:29,920
For set up a communication between Comfort panel and simotion scout 

33

00:03:30,176  -->  00:03:31,968
Classic CPU

34

00:03:32,224  -->  00:03:34,528
I have to use the device procedure

35

00:03:36,064  -->  00:03:38,880
In my device window

36

00:03:39,136  -->  00:03:40,416
I need to

37

00:03:40,928  -->  00:03:45,024
Right click with mouse and initialize my device proxy

38

00:03:46,816  -->  00:03:50,144
So will select here

39

00:03:54,752  -->  00:04:00,896
Related to simotion scout  project with MCP

40

00:04:03,456  -->  00:04:07,808
So let's go to

41

00:04:08,832  -->  00:04:10,880
For folder of projects

42

00:04:15,488  -->  00:04:21,631
This is my main folder for step 7 project you see U7

43

00:04:21,887  -->  00:04:27,007
This is related rates simotion scout  is storing the

44

00:04:27,263  -->  00:04:33,407
simotion scout  data They're here and I'm selex project MCP file

45

00:04:33,663  -->  00:04:39,807
It says the open device proxy is not possible this

46

00:04:40,063  -->  00:04:46,207
File is used in in use so unfortunately I have to close my Project

47

00:04:46,463  -->  00:04:48,511
Project Scouts

48

00:04:49,023  -->  00:04:50,559
Project on close

49

00:04:58,495  -->  00:05:04,639
You need to decide wisely during commissioning and programming your CPU and HMI

50

00:05:06,687  -->  00:05:08,479
The individual projects

51

00:05:09,503  -->  00:05:15,647
on TIA sides and classical Scout worlds that are some advantages

52

00:05:17,439  -->  00:05:20,767
At the meantime there are some disadvantages like this

53

00:05:21,535  -->  00:05:25,375
So i will click again

54

00:05:25,631  -->  00:05:29,215
And it says initializes device proxy.

55

00:05:29,727  -->  00:05:33,567
It takes couple of minutes sometime

56

00:05:33,823  -->  00:05:39,455
So you see here on the left side The Source device if

57

00:05:39,967  -->  00:05:46,111
There more than one devices you see a selection with

58

00:05:46,367  -->  00:05:51,231
Combobox for Source device know I have just one

59

00:05:51,743  -->  00:05:56,607
On the right window you'll see the device proxy data contents

60

00:05:56,863  -->  00:05:59,935
Everything should be selected

61

00:06:00,447  -->  00:06:01,983
I say okay

62

00:06:03,007  -->  00:06:07,359
Now it's going to interconnect

63

00:06:07,615  -->  00:06:12,479
My selective. data symbol browser IO list

64

00:06:12,991  -->  00:06:16,575
To device proxy TIA portal

65

00:06:19,647  -->  00:06:23,487
so initialize device proxy

66

00:06:23,743  -->  00:06:26,815
PLC1 successfully completed

67

00:06:27,583  -->  00:06:30,143
You may see on the info in general section

68

00:06:31,935  -->  00:06:32,703
Okay

69

00:06:33,215  -->  00:06:37,567
It says no alarm is objects have been transferred

70

00:06:38,591  -->  00:06:41,151
Because programs don't use ALARMS

71

00:06:42,687  -->  00:06:46,015
In next chapters we will use this option

72

00:06:46,271  -->  00:06:52,415
So on the left side you see PLC TAGs folder that are some system variables

73

00:06:54,207  -->  00:06:57,023
And you see here

74

00:06:57,279  -->  00:07:00,863
The available Source CPU itself

75

00:07:01,375  -->  00:07:07,519
Your see addressed it is empty because we didn't edit or created any IOs

76

00:07:08,799  -->  00:07:10,079
variable

77

00:07:10,335  -->  00:07:12,383
AT Global available

78

00:07:12,639  -->  00:07:18,783
Device variables you see hear some variables user-defined we have already added some

79

00:07:20,063  -->  00:07:26,207
in MCC unit tag table you see here couple of variables

80

00:07:27,487  -->  00:07:31,071
So these are the global exportable variables

81

00:07:32,607  -->  00:07:34,911
So right now we have some data

82

00:07:35,167  -->  00:07:38,239
I'm going to create and add new device

83

00:07:38,751  -->  00:07:40,799
HMI program

84

00:07:41,055  -->  00:07:43,615
i select Comfort panel

85

00:07:45,151  -->  00:07:47,967
For instance 12"

86

00:07:48,991  -->  00:07:51,039
with version

87

00:07:51,551  -->  00:07:53,343
15.1

88

00:08:09,727  -->  00:08:13,567
Okay let's use HMI advice wizard to

89

00:08:13,823  -->  00:08:16,127
Connect my PLC

90

00:08:18,431  -->  00:08:24,575
i select ethernet interface or communication and Next Step screen layout

91

00:08:25,855  -->  00:08:28,415
I will leave it as default

92

00:08:29,439  -->  00:08:34,815
For alarms and alarm windows

93

00:08:35,327  -->  00:08:37,119
let Set default

94

00:08:37,887  -->  00:08:41,471
For the HMI screen i will select all

95

00:08:42,751  -->  00:08:47,103
for buttons with set button area on the left

96

00:08:50,431  -->  00:08:51,455
Okay

97

00:08:52,479  -->  00:08:58,623
Here is the information address of device proxy conflicts with address of

98

00:08:58,879  -->  00:09:00,927
Conversation partner please correct

99

00:09:01,183  -->  00:09:03,487
The manual mode OK

100

00:09:19,615  -->  00:09:22,431
So now I see

101

00:09:22,687  -->  00:09:25,759
My screen editor with HMI

102

00:09:27,295  -->  00:09:30,879
First of all I have to arrange

103

00:09:31,391  -->  00:09:37,535
My panel settings and communication settings here will see that

104

00:09:37,791  -->  00:09:43,935
are Two different purple profibus ports simotion sites and 3 different

105

00:09:44,191  -->  00:09:44,959
 green

106

00:09:45,215  -->  00:09:48,031
profinet ports

107

00:09:48,543  -->  00:09:51,359
I just clicked twice

108

00:09:54,943  -->  00:10:01,087
After you see here device. I'm going to use the network view it's connected

109

00:10:01,599  -->  00:10:02,879
with

110

00:10:04,159  -->  00:10:08,767
PN IE ex ports you see here the default IP address

111

00:10:10,303  -->  00:10:14,399
The other one is piano x1

112

00:10:14,655  -->  00:10:16,703
The other one is PNIE

113

00:10:18,495  -->  00:10:21,567
Let's say this service port

114

00:10:22,079  -->  00:10:25,407
It's really important to enter

115

00:10:25,919  -->  00:10:30,783
I guess some information here

116

00:10:37,951  -->  00:10:41,279
Service port

117

00:10:45,375  -->  00:10:46,655
So

118

00:10:47,935  -->  00:10:48,959
Other one

119

00:10:53,311  -->  00:10:55,615
with ip adress

120

00:10:57,151  -->  00:10:58,687
2.1

121

00:10:58,943  -->  00:11:02,783
Let's check i can open my project again

122

00:11:03,551  -->  00:11:05,599
Because the device proxy

123

00:11:05,855  -->  00:11:07,391
Is finished

124

00:11:18,655  -->  00:11:21,983
So let's check my Hardware

125

00:11:22,239  -->  00:11:23,775
Find IP settings

126

00:11:28,383  -->  00:11:29,919
with net pro

127

00:11:36,831  -->  00:11:41,951
You will see here the PNIO port X150

128

00:11:42,463  -->  00:11:43,743
1.1

129

00:11:50,911  -->  00:11:52,447
This one

130

00:11:54,495  -->  00:11:56,287
Let's say

131

00:12:02,687  -->  00:12:05,247
and this one is

132

00:12:10,879  -->  00:12:17,023
So the IP addresses must be located at

133

00:12:17,279  -->  00:12:19,839
same Network settings subnet mask

134

00:12:20,607  -->  00:12:22,399
2.1

135

00:12:23,423  -->  00:12:25,215
I need to be

136

00:12:25,727  -->  00:12:28,543
2.2 for example

137

00:12:31,615  -->  00:12:32,895
Okay

138

00:12:36,223  -->  00:12:38,015
You see here

139

00:12:38,527  -->  00:12:40,319
All of the connections

140

00:12:42,623  -->  00:12:46,463
device proxy

141

00:12:46,975  -->  00:12:52,351
there is a ethernet line let's compile the HMI side

142

00:12:58,751  -->  00:13:02,847
compile is finished with no error

143

00:13:08,991  -->  00:13:12,575
So it's this case I've used this port

144

00:13:13,343  -->  00:13:16,159
Before I want to simulate

145

00:13:17,183  -->  00:13:23,327
The HMI when runtime on my PC then I should switch to service port

146

00:13:23,583  -->  00:13:26,143
 with simulation

147

00:13:28,191  -->  00:13:33,311
So you see your connections and HMI connections

148

00:13:36,639  -->  00:13:40,223
Also at this window

149

00:13:40,735  -->  00:13:43,039
There's one HMI connection

150

00:13:44,831  -->  00:13:50,463
I can change or adjust my connection settings here

151

00:13:54,047  -->  00:13:55,327
To this one

152

00:13:56,095  -->  00:13:57,631
Service port

153

00:13:57,887  -->  00:13:59,935
Then I have to

154

00:14:01,727  -->  00:14:06,079
Arrange my IP address of HMI for sure

155

00:14:14,783  -->  00:14:17,087
So let's say

156

00:14:31,935  -->  00:14:33,727
on the network

157

00:14:34,495  -->  00:14:36,543
i will connect service port Network

158

00:14:39,359  -->  00:14:40,895
Let's check again

159

00:14:42,943  -->  00:14:44,735
now it's okay

160

00:14:48,063  -->  00:14:50,879
I will compile again the HMI

161

00:14:51,135  -->  00:14:52,671
with New settings

162

00:14:54,719  -->  00:14:55,999
So it is done

163

00:14:56,511  -->  00:15:00,863
Now I'm going to use some variable on HMI screen

164

00:15:02,911  -->  00:15:04,959
I opened the root screen

165

00:15:06,751  -->  00:15:08,031
So

166

00:15:08,287  -->  00:15:12,895
I'm going to drag and drop some variable here

167

00:15:13,407  -->  00:15:14,943
Gbo true bit

168

00:15:20,319  -->  00:15:23,647
GBO false bit

169

00:15:25,951  -->  00:15:27,999
Integer variable

170

00:15:29,279  -->  00:15:31,583
Is possible to

171

00:15:32,351  -->  00:15:35,935
Set increase or decrease some variables

172

00:15:38,239  -->  00:15:40,799
Let's say

173

00:15:45,663  -->  00:15:47,199
Increase tag

174

00:15:48,479  -->  00:15:51,295
You can also say from the list

175

00:15:53,343  -->  00:15:55,135
PLC tags

176

00:15:55,391  -->  00:15:56,927
MCC units

177

00:15:57,183  -->  00:15:58,463
Case test

178

00:16:00,767  -->  00:16:01,791
Okay

179

00:16:03,327  -->  00:16:06,143
It's another available case tests

180

00:16:09,983  -->  00:16:13,567
Let's arrange the items

181

00:16:20,479  -->  00:16:24,575
And to some changes on text format

182

00:16:26,111  -->  00:16:29,951
on layout or characteristics

183

00:16:32,511  -->  00:16:38,399
Font full-size is possible it depends on your choice

184

00:16:39,679  -->  00:16:41,215
input outputs

185

00:16:47,615  -->  00:16:49,919
Okay let's save project

186

00:16:52,479  -->  00:16:56,575
Now I'll try to go open to simotion simulation

187

00:16:57,087  -->  00:17:01,695
i will select Simosim accept changes

188

00:17:01,951  -->  00:17:05,279
Are they going to do start yes

189

00:17:08,095  -->  00:17:10,911
So it's powered up

190

00:17:11,423  -->  00:17:16,799
Are select save and compile and go online

191

00:17:17,823  -->  00:17:18,847
And

192

00:17:19,359  -->  00:17:22,943
Download Project to Simulation

193

00:17:26,783  -->  00:17:30,367
It takes a few seconds

194

00:17:43,423  -->  00:17:49,311
So download completed now

195

00:17:49,823  -->  00:17:51,359
Now it's running

196

00:17:52,127  -->  00:17:55,199
Let's check the Diagnostics

197

00:18:02,111  -->  00:18:03,391
Okay

198

00:18:03,903  -->  00:18:06,975
You'll see here are simulation running

199

00:18:07,999  -->  00:18:11,327
Let's start HMI runtime

200

00:18:11,583  -->  00:18:13,375
i will select HMI

201

00:18:13,631  -->  00:18:16,447
and click here for start the Simulation

202

00:18:19,775  -->  00:18:23,871
compiled again and started

203

00:18:25,663  -->  00:18:27,711
Connection established

204

00:18:27,967  -->  00:18:29,759
Okay very good

205

00:18:30,783  -->  00:18:36,927
Now I see here my always true is one and always supposed to be

206

00:18:37,183  -->  00:18:43,327
Is logic 0 i see here some integer variable as value

207

00:18:43,583  -->  00:18:44,607
100

208

00:18:45,119  -->  00:18:47,679
When I click the button

209

00:18:47,935  -->  00:18:52,287
You see hear my other variable is increasing by one

210

00:18:53,311  -->  00:18:57,663
Let's check on the simotion side

211

00:19:07,903  -->  00:19:11,999
Okay it's symbol

212

00:19:12,767  -->  00:19:18,911
you see here my Global device available my gi16 integer

213

00:19:19,167  -->  00:19:20,191
Available

214

00:19:20,447  -->  00:19:22,495
Status value is hundreds

215

00:19:25,823  -->  00:19:31,967
My other integer variable locates at MCC units AS Global exportable

216

00:19:32,223  -->  00:19:35,551
variable I see here at symbol browser

217

00:19:36,063  -->  00:19:40,927
At my current status value is 6

218

00:19:41,183  -->  00:19:46,559
So it's communicating between simosim and HMI on runtime

219

00:19:47,839  -->  00:19:50,655
At this point

220

00:19:51,167  -->  00:19:57,311
It's important to know that's your HMI runtime setting depends on set pg pc

221

00:19:57,567  -->  00:19:58,591
Interface

222

00:20:01,407  -->  00:20:05,503
so If you get any communication errors

223

00:20:05,759  -->  00:20:11,903
This is the first place you have to check for step 7 online

224

00:20:12,159  -->  00:20:13,951
My ethernet adapter

225

00:20:14,207  -->  00:20:17,535
Is selected as gigabit Ethernet controller

226

00:20:18,815  -->  00:20:24,959
So that's okay because now I music to device adapter for simotion

227

00:20:25,215  -->  00:20:27,263
And simosim

228

00:20:28,287  -->  00:20:34,431
I have make necessary adaptations in TIA portal

229

00:20:34,687  -->  00:20:40,831
at Network view to set up the communication between runtime and simosim

230

00:20:45,695  -->  00:20:46,463
So

231

00:20:46,719  -->  00:20:50,559
At this chapter we see

232

00:20:50,815  -->  00:20:53,887
TIA portal integration and device proxy

233

00:20:57,983  -->  00:20:59,775
and You're able to do

234

00:21:00,031  -->  00:21:06,175
with yourself some additional examples or exercises with the system after

235

00:21:06,431  -->  00:21:08,735
 you don't let the necessary

236

00:21:08,991  -->  00:21:15,135
Project backups or you can on the other hand just create your own

237

00:21:15,391  -->  00:21:18,976
Project with TIA portal it's also possible

238

00:21:20,000  -->  00:21:26,144
Okay I forgot to mention about what will happen

239

00:21:27,680  -->  00:21:33,824
The user create new variable on simotion side so let's do it

240

00:21:35,616  -->  00:21:38,688
Now I'm going to create

241

00:21:38,944  -->  00:21:43,808
Some variable Global device variable list

242

00:21:44,576  -->  00:21:50,720
Some GI32 double integer

243

00:21:55,840  -->  00:22:00,192
For real variable test 1

244

00:22:00,448  -->  00:22:02,752
Is real

245

00:22:03,008  -->  00:22:09,152
I hit save and compile

246

00:22:09,920  -->  00:22:12,992
After that I will go online

247

00:22:16,064  -->  00:22:22,208
You see here the difference I'm going to download the project

248

00:22:22,464  -->  00:22:24,000
stop mode Yes

249

00:22:25,280  -->  00:22:31,424
So let's start again is in run mode so let's check

250

00:22:31,680  -->  00:22:33,472
All run time

251

00:22:33,728  -->  00:22:39,872
Now you see unfortunately our communication is

252

00:22:40,128  -->  00:22:44,224
Interrupted you see the sharp codes ####

253

00:22:44,480  -->  00:22:46,272
And input output boxes

254

00:22:46,784  -->  00:22:52,928
After I created a new variable old available list and absolute addressing

255

00:22:53,184  -->  00:22:58,816
Regulated so I lost communication let's try

256

00:22:59,072  -->  00:23:03,168
Then closed the window and compile TIA portal again

257

00:23:04,960  -->  00:23:07,264
Let's compile

258

00:23:09,824  -->  00:23:11,872
Let's set

259

00:23:12,128  -->  00:23:14,176
Runtime mode and starts

260

00:23:16,480  -->  00:23:21,344
So error inconsistenty check

261

00:23:22,624  -->  00:23:28,768
You get the error messages that means there's some complication

262

00:23:29,024  -->  00:23:35,168
Line is active but the list on the HMI site for device proxy

263

00:23:36,448  -->  00:23:38,240
it is not correct

264

00:23:38,496  -->  00:23:40,544
So what should I do?

265

00:23:43,872  -->  00:23:50,016
I need to go and device and  networks right connect to device proxy

266

00:23:50,272  -->  00:23:53,088
Need to update the data

267

00:23:53,856  -->  00:23:57,696
So I'm going to repeat the procedure

268

00:23:57,952  -->  00:24:01,024
First I have to close the project

269

00:24:02,048  -->  00:24:08,192
And with this way it costs me some time for sure

270

00:24:08,448  -->  00:24:12,800
So it says negative thing of course

271

00:24:16,640  -->  00:24:18,176
Let's updates

272

00:24:18,688  -->  00:24:22,272
Device Proxy of simotion CPU

273

00:24:24,064  -->  00:24:26,880
You'll see here some date and time

274

00:24:27,904  -->  00:24:30,464
On the left side front device proxy

275

00:24:31,232  -->  00:24:37,376
Here is my update device proxy data from Project

276

00:24:38,144  -->  00:24:39,936
Let's say

277

00:24:40,192  -->  00:24:41,728
Update addresses

278

00:24:41,984  -->  00:24:45,568
It's our case it's not the relevant to other ones

279

00:24:46,080  -->  00:24:49,408
So I click it is updating now

280

00:24:50,176  -->  00:24:52,480
It takes some time

281

00:24:52,992  -->  00:24:55,040
Update completed

282

00:24:55,808  -->  00:25:01,952
Once we have some error here Global device variables has not been

283

00:25:02,208  -->  00:25:05,280
compiled correctly

284

00:25:07,584  -->  00:25:09,632
Let's check

285

00:25:16,288  -->  00:25:22,432
You see here are additional variables double integer and real

286

00:25:27,040  -->  00:25:33,184
I'm not going to add on HMI screen I just want to make sure my

287

00:25:34,720  -->  00:25:40,864
HMI Tags is updated so let's start simulation for runtime on HMI

288

00:25:41,120  -->  00:25:42,144
Again...

289

00:25:44,192  -->  00:25:48,288
now connection established and everything's fine

290

00:25:51,616  -->  00:25:53,920
So when I want to

291

00:25:54,176  -->  00:26:00,320
Spare some time while working with simotion and HMI at the same

292

00:26:00,576  -->  00:26:01,344
Project

293

00:26:01,856  -->  00:26:03,648
At the same time

294

00:26:04,160  -->  00:26:10,304
What can I do ? so I'm reopening my first project again

295

00:26:21,056  -->  00:26:27,200
So let's go options settings and downloads and deactivate

296

00:26:27,456  -->  00:26:30,784
HMI consistency check and click to accept

297

00:26:31,808  -->  00:26:34,368
Okay let's go online

298

00:26:38,720  -->  00:26:44,864
Now it's trying to connect to step 7 online adapter

299

00:26:45,120  -->  00:26:50,496
in real system that's not supposable so I have to

300

00:26:52,032  -->  00:26:54,848
After error just connected

301

00:26:55,104  -->  00:26:57,152
i thing because the

302

00:26:57,408  -->  00:27:00,224
Simulation is open

303

00:27:00,480  -->  00:27:04,832
sinamicsc site is not possible so I deselect sinamics side

304

00:27:05,088  -->  00:27:06,880
Okay right click

305

00:27:12,256  -->  00:27:15,584
Disconnect reconnect again

306

00:27:17,376  -->  00:27:21,216
Okay let's save and compile

307

00:27:21,728  -->  00:27:23,520
it Is successful

308

00:27:23,776  -->  00:27:28,384
I go offline I will create some available here

309

00:27:29,408  -->  00:27:32,992
and real data type Test 2

310

00:27:33,248  -->  00:27:34,784
Okay

311

00:27:35,040  -->  00:27:41,184
i will save compile again and go online

312

00:27:41,440  -->  00:27:43,744
and download my CPU

313

00:27:49,888  -->  00:27:56,032
in system of downloaded and goes stop mode it again check my HMI connection

314

00:27:57,312  -->  00:28:03,456
So you see here no I didn't lost my HMI communication and

315

00:28:03,712  -->  00:28:04,736
my data

316

00:28:04,992  -->  00:28:10,112
collected I can write and read my variables at this case

317

00:28:13,952  -->  00:28:15,488
You will see here

318

00:28:17,536  -->  00:28:23,680
So that way you should earn sometime but you need to be careful.

319

00:28:23,936  -->  00:28:28,800
during Working with real machines after you add

320

00:28:29,056  -->  00:28:35,200
And create new variables and out of more variables in your program and to use with different function blocks

321

00:28:35,456  -->  00:28:37,248
 and programs

322

00:28:37,504  -->  00:28:43,648
So it's not be guaranteed by HMI

323

00:28:43,904  -->  00:28:47,488
Your reading and writing the correct variable

324

00:28:48,000  -->  00:28:50,304
That means

325

00:28:50,816  -->  00:28:56,448
Here my variable is 100 but you're not sure

326

00:28:57,984  -->  00:29:04,128
You remember sure you're looking at the right place because

327

00:29:04,384  -->  00:29:10,528
Your absolute address will be regenerated at the other time so

328

00:29:11,040  -->  00:29:12,576
It's may be shifted

329

00:29:13,344  -->  00:29:19,488
It could be another variable and you should do some mistakes with your real systems

330

00:29:20,512  -->  00:29:26,656
So Advantage you get some time at this case but you need to be

331

00:29:26,912  -->  00:29:29,728
Careful during your commissioning

332

00:29:31,776  -->  00:29:33,568
And see you.