1

00:00:00,256  -->  00:00:05,888
so hello everyone our current chapter Is 18

2

00:00:06,400  -->  00:00:12,544
Today's topic is migration classic project to Tia portal

3

00:00:13,568  -->  00:00:15,616
So let's start

4

00:00:18,432  -->  00:00:24,576
We have here an example projects named as first project

5

00:00:24,832  -->  00:00:29,696
we used one simotion CPU and one HMI

6

00:00:31,232  -->  00:00:33,536
I'm going to

7

00:00:33,792  -->  00:00:35,328
Close the project

8

00:00:35,584  -->  00:00:39,168
Start the tia portal

9

00:00:41,472  -->  00:00:47,616
we can not use version 16 because there's no option Package simotion scout

10

00:00:47,872  -->  00:00:51,456
released with 16

11

00:00:52,480  -->  00:00:57,088
Maybe they say it in the next like with version 17

12

00:00:57,344  -->  00:01:01,696
So I will continue with version 15 service pack 1

13

00:01:03,488  -->  00:01:07,840
I will send it to you the migrate project option

14

00:01:08,096  -->  00:01:11,680
I have to answer the source path

15

00:01:13,728  -->  00:01:19,616
So there's a list year old files that can be migrated

16

00:01:19,872  -->  00:01:21,664
Step 7 project

17

00:01:22,432  -->  00:01:27,040
HMI project I'm going to choose steps 7 project

18

00:01:27,808  -->  00:01:31,648
Go to my example

19

00:01:32,672  -->  00:01:38,816
In the folder you should select here the extension. Step7p

20

00:01:41,888  -->  00:01:43,936
And I click open

21

00:01:45,216  -->  00:01:48,800
So there's a checkbox include Hardware configuration

22

00:01:50,336  -->  00:01:55,200
It's your hardware and CPU in all the project in simatic manager

23

00:01:55,456  -->  00:02:00,832
Is recognizable by TIA portal so it's not problem

24

00:02:02,112  -->  00:02:08,256
At this point there are some requirements and there is a good PDF

25

00:02:08,512  -->  00:02:10,560
Prepared by Siemens

26

00:02:10,816  -->  00:02:16,192
You can find a website and SIOS or in forums

27

00:02:16,448  -->  00:02:22,592
Used

28

00:02:22,848  -->  00:02:25,152
Your house

29

00:02:28,480  -->  00:02:34,624
Because older products at siemens site

30

00:02:34,880  -->  00:02:41,024
Before 2008 it's not possible to use with new

31

00:02:41,280  -->  00:02:45,120
new TIA portal versions so if

32

00:02:45,376  -->  00:02:51,520
You want to use your old Hardware you need to be careful about that

33

00:02:53,056  -->  00:02:55,360
i will selected wwith

34

00:02:55,616  -->  00:02:59,968
Includes Hardware configuration and the target paths

35

00:03:00,736  -->  00:03:03,808
So let's say simatic first project

36

00:03:04,064  -->  00:03:06,112
voncert

37

00:03:06,368  -->  00:03:07,392
TIA 15

38

00:03:08,160  -->  00:03:09,696
Sp1

39

00:03:09,952  -->  00:03:13,792
So let's create them migrate button

40

00:03:16,864  -->  00:03:19,680
TIA is creating a new project

41

00:03:20,192  -->  00:03:24,032
And you can track the progress

42

00:03:24,288  -->  00:03:26,592
From output window in TIA

43

00:03:34,784  -->  00:03:37,856
so Let's see what will happen

44

00:03:40,928  -->  00:03:43,488
You see in progress

45

00:03:48,096  -->  00:03:51,680
Our program is really basic

46

00:03:51,936  -->  00:03:53,216
and

47

00:03:53,728  -->  00:03:57,056
there are Just One CPU and HMI

48

00:03:59,872  -->  00:04:02,688
Even here we get an migration error

49

00:04:03,200  -->  00:04:09,344
Here in info window

50

00:04:14,464  -->  00:04:16,000
Project

51

00:04:16,512  -->  00:04:17,791
So

52

00:04:18,047  -->  00:04:20,607
That means

53

00:04:20,863  -->  00:04:25,471
HMI type is not supported by the TIA

54

00:04:26,239  -->  00:04:28,799
Because it's an old product

55

00:04:31,359  -->  00:04:32,895
So

56

00:04:35,711  -->  00:04:36,991
Let's open

57

00:04:38,527  -->  00:04:44,415
That means maybe I have to use the new version of simatic message HMI or

58

00:04:44,927  -->  00:04:46,719
And new type

59

00:04:57,215  -->  00:05:02,847
It's convert HMI device type with right click change device type

60

00:05:06,431  -->  00:05:08,991
I will choose

61

00:05:09,247  -->  00:05:10,783
Mobile panel

62

00:05:11,807  -->  00:05:14,879
Version 2

63

00:05:15,391  -->  00:05:21,535
MP 277 latest version okay

64

00:05:23,071  -->  00:05:27,167
HI screen is larger than older one

65

00:05:27,679  -->  00:05:32,031
Automatically scaled by the wincc flexible

66

00:05:32,287  -->  00:05:34,847
Save current project

67

00:05:35,103  -->  00:05:40,223
Before you do migration you have to be sure

68

00:05:40,735  -->  00:05:45,599
The programs are consistent and that's why

69

00:05:45,855  -->  00:05:48,671
You have to compile before

70

00:05:48,927  -->  00:05:51,231
Let's generate HMI data

71

00:05:52,767  -->  00:05:58,143
Otherwise you will get an error during migration in TIA

72

00:05:58,655  -->  00:06:00,959
compiled finish is close

73

00:06:01,983  -->  00:06:03,007
Yes

74

00:06:19,135  -->  00:06:22,719
This is our first attempt

75

00:06:22,975  -->  00:06:24,767
TIA created project

76

00:06:26,047  -->  00:06:27,583
Regeneration

77

00:06:31,167  -->  00:06:32,703
Let's try again

78

00:06:33,215  -->  00:06:35,263
in portal view

79

00:06:35,519  -->  00:06:37,567
migrate projects

80

00:06:37,823  -->  00:06:43,711
Select the source path again the same project include Hardware

81

00:06:44,223  -->  00:06:45,759
Let's start

82

00:06:51,903  -->  00:06:54,975
These are the old messages

83

00:06:55,231  -->  00:06:57,023
now we will try again

84

00:06:57,791  -->  00:07:00,095
And get the error

85

00:07:00,607  -->  00:07:03,679
If I click the migration log

86

00:07:04,191  -->  00:07:10,335
web-based window open in my browser so that says the same thing

87

00:07:10,591  -->  00:07:12,383
chang HMI my device type

88

00:07:12,639  -->  00:07:15,967
The source project reported documentation

89

00:07:20,063  -->  00:07:21,343
Okay

90

00:07:25,951  -->  00:07:30,815
List different version of

91

00:07:31,071  -->  00:07:32,351
TIA PORTAL for instance

92

00:07:34,143  -->  00:07:36,447
Version 14

93

00:07:38,495  -->  00:07:43,103
By the way your CPU type and firmware

94

00:07:43,615  -->  00:07:48,479
Also is important that you have to

95

00:07:48,735  -->  00:07:54,879
Be installed required option packages for the TIA portal for instance scout tia

96

00:07:55,903  -->  00:07:59,743
and wincc HMI advanced

97

00:08:01,791  -->  00:08:04,351
let select Migrate project

98

00:08:05,631  -->  00:08:07,679
Send the same project

99

00:08:08,703  -->  00:08:10,751
Includes Hardware

100

00:08:11,007  -->  00:08:12,799
Refer verison 14

101

00:08:28,159  -->  00:08:34,303
I'm empty new project created by the TIA portal and is starting now

102

00:08:34,559  -->  00:08:40,703
Try to migrate to step manager project exporting project.

103

00:08:41,471  -->  00:08:44,543
Normally takes couple of minutes

104

00:08:45,823  -->  00:08:50,687
and you see here a different kind of error messages

105

00:08:54,015  -->  00:08:59,135
module in rack slot 2 cannot be migrated model is not supported

106

00:08:59,391  -->  00:09:02,463
Other interface module same message...

107

00:09:02,719  -->  00:09:07,327
This cannot be my create and error occurred during the migration

108

00:09:08,351  -->  00:09:14,239
Now regrets some error messages from Simotion site

109

00:09:18,591  -->  00:09:21,407
Then you'll see here web based message

110

00:09:23,455  -->  00:09:24,479
Okay

111

00:09:27,551  -->  00:09:31,903
Let's go and check my winCC flexible version

112

00:10:06,463  -->  00:10:12,607
I will check here until reports of which type of HMI with support

113

00:10:13,375  -->  00:10:14,911
basic panels

114

00:10:15,423  -->  00:10:18,495
Mobile panels

115

00:10:19,263  -->  00:10:21,311
270 series

116

00:10:23,871  -->  00:10:26,175
And I see here

117

00:10:27,199  -->  00:10:28,991
The MLFB number

118

00:10:29,247  -->  00:10:31,807
with Real version 12

119

00:10:34,111  -->  00:10:37,695
Yeah I will try with this one

120

00:10:38,719  -->  00:10:41,535
But I think the version is different

121

00:11:11,999  -->  00:11:15,839
Or just selected runtime

122

00:11:16,351  -->  00:11:21,727
To compete complete to migration is another way

123

00:11:26,591  -->  00:11:32,223
Also the reservation will be changed then you need to arrange your screens again

124

00:11:34,783  -->  00:11:36,063
Let's save

125

00:11:46,047  -->  00:11:48,095
first generate

126

00:11:53,727  -->  00:11:56,031
Let's try again

127

00:11:56,287  -->  00:11:58,591
to create project

128

00:11:59,103  -->  00:12:01,407
Select the same project

129

00:12:01,663  -->  00:12:03,199
include Hardware

130

00:12:03,455  -->  00:12:04,735
New path

131

00:12:10,367  -->  00:12:16,511
So this time I didn't closed the step 7 manager and the winccflexible

132

00:12:18,047  -->  00:12:20,351
So I get an error

133

00:12:20,863  -->  00:12:23,423
For that project may be opened

134

00:12:23,679  -->  00:12:27,519
I have to close the applications

135

00:12:28,543  -->  00:12:30,079
Okay

136

00:12:41,855  -->  00:12:45,183
Let's try again migrate project

137

00:12:45,951  -->  00:12:49,023
Same project include Hardware

138

00:12:56,959  -->  00:12:59,519
Let's see what would happen this time

139

00:13:04,895  -->  00:13:07,199
Okay

140

00:13:07,711  -->  00:13:10,527
with verison 15 sp1

141

00:13:11,039  -->  00:13:17,183
I got the same error message on simotions use Hardware

142

00:13:18,207  -->  00:13:22,815
can not be migrated because some modules are really old

143

00:13:23,071  -->  00:13:24,095
So

144

00:13:24,351  -->  00:13:26,399
First of all

145

00:13:27,167  -->  00:13:28,447
i will go

146

00:13:28,959  -->  00:13:33,567
Hardware and replace the old modules or delete

147

00:13:35,871  -->  00:13:38,431
That means TIA

148

00:13:39,199  -->  00:13:43,807
Don't recognize my hardware and models

149

00:13:55,071  -->  00:13:58,655
so Let's try this one

150

00:13:59,935  -->  00:14:01,215
Yes

151

00:14:09,151  -->  00:14:15,295
There are some radical changes with TIA version 13 by the way

152

00:14:15,807  -->  00:14:21,951
It's like a milestone siemens TIA world if you want to migrate all the projects

153

00:14:22,207  -->  00:14:26,303
 for instance from version

154

00:14:26,559  -->  00:14:29,631
from version 11

155

00:14:29,887  -->  00:14:36,031
to version 14 it's not possible to do that directly with version 14

156

00:14:36,287  -->  00:14:42,431
You have to use first version 13 migrate from version 11 to 13

157

00:14:42,687  -->  00:14:48,831
So after that as second step you are able to go one step up and migrate

158

00:14:49,087  -->  00:14:54,975
Take your project to version 14 or version 15 whatever you want

159

00:14:55,231  -->  00:15:01,375
So keep in that one's right now I'm working is simatic manager do hardware config

160

00:15:01,631  -->  00:15:06,495
i have deleted my old modules

161

00:15:06,751  -->  00:15:10,591
and let's save and compile again

162

00:15:11,103  -->  00:15:15,455
So I will try again with Tia portal

163

00:15:19,295  -->  00:15:21,343
In that case

164

00:15:22,879  -->  00:15:27,999
Eventually at the end I think we will find out that

165

00:15:28,511  -->  00:15:30,047
our HMI

166

00:15:31,583  -->  00:15:37,727
MP277 HMI is possible to migrate with version 14

167

00:15:37,983  -->  00:15:42,079
It's not possible to migrate with version 15 Service Pack 1

168

00:15:43,615  -->  00:15:44,895
we will see that

169

00:15:45,663  -->  00:15:47,199
at This chapter

170

00:15:48,223  -->  00:15:51,551
In the next couple of minutes I hope so

171

00:15:53,087  -->  00:15:59,231
now i close the net Pro and hardware config that's why I have to wait a couple of minutes right

172

00:16:01,535  -->  00:16:06,143
because I can't control my mouse and cursor are here

173

00:16:07,423  -->  00:16:11,775
now first

174

00:16:12,031  -->  00:16:13,567
Let's try with

175

00:16:13,823  -->  00:16:15,359
TIA portal

176

00:16:15,871  -->  00:16:21,759
15 with flexible pc runtime and let's see

177

00:16:22,783  -->  00:16:25,855
What will happen in this time.

178

00:16:27,647  -->  00:16:30,719
And after that I will

179

00:16:30,975  -->  00:16:34,815
Replace the HMI back to

180

00:16:35,071  -->  00:16:36,863
MP series

181

00:16:37,119  -->  00:16:39,935
Try again with version 14

182

00:16:40,959  -->  00:16:45,311
Let's see the difference between versions

183

00:16:53,759  -->  00:16:58,879
so It takes couple of minutes unfortunately I have to wait

184

00:17:08,095  -->  00:17:09,631
So now I'm ready

185

00:17:10,911  -->  00:17:13,727
Let's try version 15

186

00:17:14,239  -->  00:17:20,383
Migrate project it's a little annoying but sometimes you just can't

187

00:17:21,151  -->  00:17:27,295
Do anything about that so you have to find another solution or another possibility

188

00:17:27,551  -->  00:17:33,695
You have to look from another point of view to solve your

189

00:17:33,951  -->  00:17:35,231
Problem

190

00:17:35,487  -->  00:17:38,815
Sometimes it's not logical

191

00:17:39,327  -->  00:17:43,679
What's your game experience time my time

192

00:17:44,447  -->  00:17:46,239
Let's see...

193

00:17:56,735  -->  00:17:59,039
Remaining time in seconds

194

00:17:59,551  -->  00:18:01,343
Creating target project

195

00:18:01,599  -->  00:18:05,439
I think we're passed this time

196

00:18:05,951  -->  00:18:11,071
TIA creating are objects in new project

197

00:18:26,687  -->  00:18:30,783
When you are working with solid state drives

198

00:18:31,039  -->  00:18:33,087
it is Really faster than

199

00:18:33,599  -->  00:18:36,159
Conventional hard drives

200

00:18:37,439  -->  00:18:39,231
Now I'm working

201

00:18:39,999  -->  00:18:41,279
Together

202

00:18:41,535  -->  00:18:43,327
so Sometimes

203

00:18:44,095  -->  00:18:47,679
it Takes longer time than usual

204

00:18:49,471  -->  00:18:54,335
If you have a bigger SSD drive like 1 gigabytes

205

00:18:56,127  -->  00:18:57,407
You have

206

00:18:58,175  -->  00:18:59,199
a lot of space

207

00:18:59,455  -->  00:19:02,271
And as faster program to work

208

00:19:04,063  -->  00:19:10,207
And migration project completed with warnings here the warnings of the migration scout must be compiled

209

00:19:15,839  -->  00:19:21,983
In this way and Alignment is performed on telegrams sync operation

210

00:19:23,263  -->  00:19:24,287
and so on...

211

00:19:24,799  -->  00:19:28,895
So that means you have to download your

212

00:19:29,151  -->  00:19:32,735
TIA Scout project against Hardware

213

00:19:36,063  -->  00:19:38,367
Let's see

214

00:19:39,391  -->  00:19:44,511
And you can see here or HMI runtime with screen 1

215

00:19:50,655  -->  00:19:55,519
Is our design HMI screen one

216

00:19:55,775  -->  00:19:58,335
You see here simotion scout

217

00:19:58,591  -->  00:20:02,687
When I open device and networks on tia portal

218

00:20:03,199  -->  00:20:07,039
I already installed scout tia

219

00:20:08,831  -->  00:20:13,439
So I'm able to work with

220

00:20:14,207  -->  00:20:16,255
New version of CPUs

221

00:20:16,511  -->  00:20:18,559
Hardware looks like this

222

00:20:24,447  -->  00:20:29,055
so Similar menus but different design

223

00:20:29,311  -->  00:20:35,199
You will learn something new

224

00:20:35,711  -->  00:20:39,551
During same thing

225

00:20:39,807  -->  00:20:45,951
Yeah here in simotion tags when we click to show all

226

00:20:46,207  -->  00:20:52,351
here normally all of the axes we didn't compiled so

227

00:20:54,143  -->  00:20:57,215
First we have to compile or simotion

228

00:20:59,263  -->  00:21:05,407
And in TIA portal you're compiling the hardware sides of the simotion

229

00:21:07,455  -->  00:21:11,551
If you double click motion configuration

230

00:21:12,575  -->  00:21:16,416
simotion with TIA option with opens

231

00:21:19,232  -->  00:21:21,024
new window It's my

232

00:21:21,280  -->  00:21:23,328
Desktop screen

233

00:21:24,352  -->  00:21:26,144
Or it's monitor

234

00:21:33,568  -->  00:21:39,712
It's really similar to simotion scout classic

235

00:21:39,968  -->  00:21:43,808
But there are some differences it menus

236

00:21:46,368  -->  00:21:47,904
Pros and cons

237

00:21:48,416  -->  00:21:52,768
Maybe we will examine next chapters

238

00:21:53,024  -->  00:21:57,888
Compare the differences advantages disadvantages

239

00:21:59,936  -->  00:22:01,984
So far

240

00:22:02,240  -->  00:22:05,312
Looks like similar

241

00:22:05,824  -->  00:22:08,640
Let's save and compile our CPU

242

00:22:20,160  -->  00:22:21,696
Okay

243

00:22:23,744  -->  00:22:27,328
Working a little bit slower than the classic scout

244

00:22:28,352  -->  00:22:29,888
At the background

245

00:22:30,144  -->  00:22:32,448
You will see here window

246

00:22:32,960  -->  00:22:39,104
now i Get the related data system variables MCC unit global

247

00:22:39,360  -->  00:22:40,896
Device variables this here

248

00:22:41,920  -->  00:22:45,760
So

249

00:22:52,672  -->  00:22:57,024
Let's change our device back to

250

00:22:58,560  -->  00:23:00,096
HMI

251

00:23:01,632  -->  00:23:06,752
I'm going to use mobile HMI 10 inches

252

00:23:07,008  -->  00:23:08,800
with this version

253

00:23:13,664  -->  00:23:15,712
Let's say okay

254

00:23:24,928  -->  00:23:27,232
Save projects

255

00:23:27,744  -->  00:23:30,048
from compile HMI

256

00:23:48,224  -->  00:23:52,832
You see here the current progress is still compiling

257

00:23:53,088  -->  00:23:58,720
I'm you get some error messages as invalid symbols

258

00:24:01,536  -->  00:24:04,352
so PLC tag

259

00:24:05,120  -->  00:24:06,400
is Undefined

260

00:24:06,656  -->  00:24:09,216
Please check the connection

261

00:24:09,472  -->  00:24:12,288
Right now we don't have any connection

262

00:24:12,544  -->  00:24:14,592
Between HMI and CPU

263

00:24:14,848  -->  00:24:17,408
so you have to make a connection

264

00:24:18,176  -->  00:24:21,504
Let's say service ports

265

00:24:22,016  -->  00:24:24,064
and correct subnet mask

266

00:24:28,416  -->  00:24:30,720
For HMI connection

267

00:24:33,280  -->  00:24:36,608
You see here simotion Port this one

268

00:24:42,240  -->  00:24:47,872
Let's see details looks like fine

269

00:24:56,832  -->  00:25:00,928
I will replace the old connection here

270

00:25:02,720  -->  00:25:04,512
Delete

271

00:25:06,560  -->  00:25:08,352
So this is the current

272

00:25:09,120  -->  00:25:13,216
Connection list check the tags

273

00:25:13,728  -->  00:25:15,008
Show all tags

274

00:25:15,520  -->  00:25:21,664
The connection was is incorrect HMI Connection

275

00:25:24,736  -->  00:25:30,880
Yes you take is still in red color that means no

276

00:25:31,136  -->  00:25:37,280
Interconnection and I have to rewire or synchronize the PLC tag list

277

00:25:39,840  -->  00:25:45,984
During a project that are some options to do sync PLC tags with Wincc

278

00:25:50,080  -->  00:25:56,224
I said your paths of PLC tags match and desselect

279

00:25:56,480  -->  00:26:00,576
the checkBox and click synchronize

280

00:26:01,088  -->  00:26:07,232
Unfortunately couldn't do that because there are some addresses

281

00:26:07,488  -->  00:26:10,816
here but symbols are missing

282

00:26:11,328  -->  00:26:17,472
So let's try with the type and absolute address match

283

00:26:17,728  -->  00:26:19,776
And synchronize

284

00:26:23,616  -->  00:26:27,968
Because at this case I have here some absolute addresses

285

00:26:29,504  -->  00:26:32,576
now I'm able to connect to tags

286

00:26:33,344  -->  00:26:35,904
PLC TAGS list is updated

287

00:26:38,208  -->  00:26:41,024
So let's compile HMI

288

00:26:41,536  -->  00:26:42,816
And try again

289

00:26:45,376  -->  00:26:51,520
error Message related Administration password default password is

290

00:26:51,776  -->  00:26:54,080
Hundred

291

00:26:54,336  -->  00:26:57,920
for siemens hmis ok

292

00:27:05,344  -->  00:27:07,136
on hmi side

293

00:27:07,648  -->  00:27:12,768
Is consistent and ready I will check

294

00:27:13,280  -->  00:27:17,632
scout tia side with simosim

295

00:27:18,144  -->  00:27:19,680
Yes

296

00:27:25,056  -->  00:27:31,200
It looks like a similar to Classic Scout but attention please right now working with tia

297

00:27:35,552  -->  00:27:38,112
I hit the connect the target system

298

00:27:38,880  -->  00:27:45,024
So I'm connected to simulation I'm going to download and follow the same steps

299

00:27:45,280  -->  00:27:49,632
At the beginning of this chapter

300

00:27:51,680  -->  00:27:55,776
So let's take

301

00:27:56,032  -->  00:28:01,152
A few seconds to download project is resetting the project target system

302

00:28:03,200  -->  00:28:05,504
Software power on

303

00:28:05,760  -->  00:28:07,296
Start up again

304

00:28:08,320  -->  00:28:10,112
Technology packages will be loaded for

305

00:28:10,368  -->  00:28:12,416
The first time

306

00:28:13,440  -->  00:28:19,584
Sources has been changed and project downloaded I will set remote again

307

00:28:20,864  -->  00:28:27,008
Now I switch back to TAI portal HMI side I will click again the starts with a simulation

308

00:28:32,640  -->  00:28:36,480
And if you're lucky you will get

309

00:28:36,736  -->  00:28:38,784
Your connection running

310

00:28:40,576  -->  00:28:44,160
Let's check our buttons is working well

311

00:28:44,416  -->  00:28:46,720
Our communication established

312

00:28:46,976  -->  00:28:48,512
so That's it

313

00:28:48,768  -->  00:28:51,328
Let's close the runtime

314

00:28:53,632  -->  00:28:59,776
Let's close simotion scout tia and some simosim

315

00:29:00,032  -->  00:29:02,848
So if you want to close your project

316

00:29:03,104  -->  00:29:04,896
On TIA site

317

00:29:05,408  -->  00:29:11,552
There's a warning because your scout tia

318

00:29:11,808  -->  00:29:13,088
is open so Please close

319

00:29:15,392  -->  00:29:20,768
First you have to close your scout tia window

320

00:29:22,560  -->  00:29:26,144
so Let's go back and

321

00:29:26,912  -->  00:29:29,984
Open the manager and consist of winccflexible

322

00:29:34,336  -->  00:29:40,224
And change the HMI type here

323

00:29:47,392  -->  00:29:50,976
So migration to TIA Portal starting

324

00:30:00,448  -->  00:30:04,800
I will select it again

325

00:30:05,056  -->  00:30:08,384
change device type and start to old one

326

00:30:08,896  -->  00:30:12,480
With this okay

327

00:30:24,768  -->  00:30:29,376
restarted generated and to be sure

328

00:30:29,632  -->  00:30:35,776
That everything is consistent with is finished I will close

329

00:30:51,136  -->  00:30:56,512
so Let's try with version 14 to do the migration

330

00:30:57,024  -->  00:31:02,400
I'm selected the project is same project and include the hardware

331

00:31:04,704  -->  00:31:08,800
Let's see what will happen in this case

332

00:31:15,968  -->  00:31:18,272
So I get an error

333

00:31:19,296  -->  00:31:24,416
You see here the module is new version is not supported

334

00:31:24,672  -->  00:31:26,208
Okay

335

00:31:26,464  -->  00:31:32,608
Let's replace the CPU type with old firmware version

336

00:31:37,216  -->  00:31:40,544
I will go on Hardware

337

00:31:41,568  -->  00:31:43,616
And right click

338

00:31:44,640  -->  00:31:50,528
On the rail let's say replace the object with same type of CPU

339

00:31:51,552  -->  00:31:53,600
D425-2

340

00:31:54,624  -->  00:32:00,768
Two different kind of CPU allow with profibus model or profinet

341

00:32:01,792  -->  00:32:07,680
unfortunately it's possible to go One Step Up

342

00:32:08,192  -->  00:32:10,496
at this case

343

00:32:14,080  -->  00:32:19,712
There is no way to do a go back one step

344

00:32:21,248  -->  00:32:22,272
So

345

00:32:26,880  -->  00:32:31,232
You see here on the available CPUs

346

00:32:32,512  -->  00:32:34,560
Another way to do that

347

00:32:38,400  -->  00:32:40,448
you can export

348

00:32:41,216  -->  00:32:46,080
Your variables and Tos as examine XML

349

00:32:46,592  -->  00:32:51,712
External file that creates your see-through again

350

00:32:52,480  -->  00:32:56,320
Import your exported data

351

00:32:56,576  -->  00:33:00,928
to new older firmware version CPU

352

00:33:01,184  -->  00:33:02,464
after that

353

00:33:02,720  -->  00:33:07,840
You are able to continue with your old system and migrate to TIA portal

354

00:33:13,472  -->  00:33:17,056
It's good example

355

00:33:18,336  -->  00:33:21,152
For you at this case

356

00:33:21,408  -->  00:33:27,552
Of course there are always some minor things or untold trues

357

00:33:30,112  -->  00:33:31,648
Between versions

358

00:33:32,672  -->  00:33:38,816
Each updates in software that are some new features are so that our some bugs

359

00:33:39,328  -->  00:33:40,608
Comes together

360

00:33:42,656  -->  00:33:48,800
If you're using the product

361

00:33:49,056  -->  00:33:51,360
day by day with new project you gain More experienced so

362

00:33:51,616  -->  00:33:53,408
At this point

363

00:33:54,432  -->  00:34:00,320
I want to show you and pdf file on website

364

00:34:01,088  -->  00:34:07,232
here in SIOS

365

00:34:08,512  -->  00:34:14,656
And I go see my support sites at answer here my favorite for Searching

366

00:34:15,680  -->  00:34:21,824
Also that I get the compatibility list of software products in Simotion

367

00:34:22,080  -->  00:34:23,616
 environments

368

00:34:24,640  -->  00:34:26,432
For different versions

369

00:34:27,456  -->  00:34:29,248
And

370

00:34:29,504  -->  00:34:32,064
it is A good thing to

371

00:34:32,320  -->  00:34:37,440
Be sure if my scout is comfortable

372

00:34:37,952  -->  00:34:40,256
with windows

373

00:34:41,024  -->  00:34:47,168
And if you wonder if it's possible to install for example version

374

00:34:47,424  -->  00:34:50,496
5.3 to Windows 7

375

00:34:51,264  -->  00:34:52,544
You'll see here

376

00:34:52,800  -->  00:34:58,944
By the way they are different 2 different setups Scout Standalone and Scout classic

377

00:35:00,992  -->  00:35:07,136
Let's say if you are using simatic manager and it's already installed

378

00:35:07,392  -->  00:35:13,536
Your PC you're going to use the Scout option package DVDs

379

00:35:13,792  -->  00:35:16,096
Install Simotion

380

00:35:16,352  -->  00:35:21,472
On the other hand if you are not using simatic manager

381

00:35:21,984  -->  00:35:28,128
You can install Scout stand-alone on your windows so

382

00:35:28,384  -->  00:35:30,944
let see in chapter 1

383

00:35:31,200  -->  00:35:33,248
Compatibility between

384

00:35:33,504  -->  00:35:35,296
Scout and windows

385

00:35:36,832  -->  00:35:37,600
So...

386

00:35:37,856  -->  00:35:44,000
for version 5.3 Service Pack 1 is it possible to install Windows 7

387

00:35:44,256  -->  00:35:45,792
professional

388

00:35:46,048  -->  00:35:47,584
Service Pack 1

389

00:35:48,096  -->  00:35:50,656
Only 64 bit processor and

390

00:35:51,168  -->  00:35:55,008
You know operating system

391

00:35:55,264  -->  00:35:59,360
Is also possible to install Windows 10 Enterprise

392

00:36:01,664  -->  00:36:07,808
If you're searching for compatibility between different kind of softwares

393

00:36:10,112  -->  00:36:14,720
For different option packages here you will find

394

00:36:15,488  -->  00:36:18,816
Requirements and information

395

00:36:20,608  -->  00:36:26,240
Between CFC and DCC also there's some issues

396

00:36:27,264  -->  00:36:28,800
If you are using

397

00:36:29,312  -->  00:36:32,128
The CFC 7.0

398

00:36:32,384  -->  00:36:35,200
PCS7 for instance

399

00:36:35,712  -->  00:36:40,064
You are able to use DCC For simotion version

400

00:36:40,320  -->  00:36:42,880
2.0 Service Pack 1 at this case

401

00:36:46,464  -->  00:36:52,608
Another good way to use

402

00:36:52,864  -->  00:36:59,008
Virtual machines on the same PC to prevent

403

00:36:59,776  -->  00:37:03,872
To use incompatible

404

00:37:04,128  -->  00:37:08,480
versions because there are a lot of Siemens products and options

405

00:37:08,736  -->  00:37:14,880
If you are using both simatic products simotion products and sinumerik products

406

00:37:15,136  -->  00:37:21,280
sometimes is not possible to install all of them in one piece and one harddrive so

407

00:37:21,792  -->  00:37:26,400
That case you have to find the solution

408

00:37:26,912  -->  00:37:32,288
I think the virtual environment is one of them

409

00:37:35,872  -->  00:37:38,432
And you see here simotion kernel

410

00:37:38,688  -->  00:37:40,480
with Cf carts

411

00:37:41,248  -->  00:37:44,832
here the MLFB code of cf cards

412

00:37:45,600  -->  00:37:50,720
You don't have to keeping all of them in your mind

413

00:37:50,976  -->  00:37:52,768
but you are

414

00:37:53,280  -->  00:37:57,376
Already know how do you find

415

00:37:58,400  -->  00:38:00,192
Information

416

00:38:02,496  -->  00:38:08,640
about User memory controller based place for drive based platform

417

00:38:08,896  -->  00:38:11,968
here with new firmware version

418

00:38:12,480  -->  00:38:18,624
Sometimes you get more retentive user variable or

419

00:38:19,136  -->  00:38:20,160
More

420

00:38:20,416  -->  00:38:22,464
User memory

421

00:38:24,000  -->  00:38:25,536
with devices

422

00:38:32,448  -->  00:38:36,800
There are also some information regarding to compact flash cards

423

00:38:37,056  -->  00:38:39,616
and compatibilities

424

00:38:43,200  -->  00:38:44,736
you will see here

425

00:38:44,992  -->  00:38:48,832
simotion scout and tia portal and device proxy

426

00:38:51,136  -->  00:38:52,928
possible connections with HMI

427

00:38:53,696  -->  00:38:56,512
For instance with

428

00:38:56,768  -->  00:38:59,328
HMI version 11

429

00:38:59,584  -->  00:39:03,936
It's not possible to communicate simotion

430

00:39:04,192  -->  00:39:06,240
So it's a strange thing

431

00:39:07,008  -->  00:39:13,152
When did comfort and basic HMI panels first released unfortunately

432

00:39:13,408  -->  00:39:19,552
we were not able to use Siemens HMI products with simotion

433

00:39:19,808  -->  00:39:22,368
It's like a joke

434

00:39:22,880  -->  00:39:23,904
By the way

435

00:39:24,416  -->  00:39:27,488
It's really a strange thing for us

436

00:39:28,256  -->  00:39:32,352
But after the version 12 birth of the TIA portal unreleased

437

00:39:33,120  -->  00:39:35,680
we were able to use

438

00:39:35,936  -->  00:39:40,800
Siemens HMI products siemens simotion plc older days using winccflexible

439

00:39:47,456  -->  00:39:52,064
For many years it's a stable program now

440

00:39:53,088  -->  00:39:59,232
Each year and new version of TIA portal release and we have to keep moving

441

00:40:01,024  -->  00:40:02,304
but

442

00:40:03,072  -->  00:40:09,216
At the meantime you have to be careful about that's durng

443

00:40:09,472  -->  00:40:11,776
Project development

444

00:40:13,056  -->  00:40:18,432
And that's what I mean by I said you're getting some experience

445

00:40:18,944  -->  00:40:20,736
So

446

00:40:22,528  -->  00:40:24,576
That's all for now

447

00:40:24,832  -->  00:40:27,392
I'm closing my windows

448

00:40:27,904  -->  00:40:29,184
And manager

449

00:40:29,440  -->  00:40:31,488
and TIA portal

450

00:40:35,584  -->  00:40:39,168
so lets see you at Next chapters. Chaou.