1

00:00:01,280  -->  00:00:03,584
Chapter 32

2

00:00:04,096  -->  00:00:09,728
Scout Classic on TIA Scout comperation pros and cons

3

00:00:10,496  -->  00:00:14,848
Let's talk about and which way

4

00:00:15,360  -->  00:00:21,504
should we Choose before we begin to develop our project

5

00:00:23,808  -->  00:00:25,088
I have written

6

00:00:26,368  -->  00:00:28,928
Something in my mind

7

00:00:33,024  -->  00:00:34,304
about scout classic Today

8

00:00:35,584  -->  00:00:41,216
we still use instead of TIA scout

9

00:00:41,472  -->  00:00:44,288
it is a stable environment

10

00:00:44,544  -->  00:00:50,688
Of course that are some bugs sometimes it's Crush depends on your system PC

11

00:00:50,944  -->  00:00:53,504
Ram size or Windows

12

00:00:53,760  -->  00:00:55,296
version

13

00:00:56,064  -->  00:01:02,208
it is Sustainable and reasonable when you compared with TIA scout

14

00:01:03,232  -->  00:01:08,608
each year Almost siemens release new version of TIA scout

15

00:01:11,168  -->  00:01:12,192
still development So

16

00:01:12,448  -->  00:01:18,336
test environment with Different kind of products of firmwares already done

17

00:01:18,848  -->  00:01:23,456
That means there are a lot of questions and FAQs

18

00:01:25,504  -->  00:01:30,368
information already it you can just find easily when you have

19

00:01:31,136  -->  00:01:35,744
The problem or faced with a strange situation so

20

00:01:36,512  -->  00:01:39,584
This an advantage for classical world

21

00:01:39,840  -->  00:01:43,424
it is Possible to convert TIA scout sometime later on

22

00:01:43,680  -->  00:01:44,192
Yep

23

00:01:44,448  -->  00:01:50,592
If you begin to program your CPU classic scout simatic manager

24

00:01:50,848  -->  00:01:54,176
simotion Scouts at wincc flexible

25

00:01:54,432  -->  00:02:00,576
After that is possible to convert to TIA from classical world ofcourse

26

00:02:03,136  -->  00:02:06,208
winccflexible integration

27

00:02:06,720  -->  00:02:08,256
Is only possible

28

00:02:08,512  -->  00:02:11,328
When you are working with Old panels

29

00:02:12,608  -->  00:02:18,240
nowadays MP or TP series old panels as

30

00:02:20,288  -->  00:02:24,896
Selling as a spare parts so that's why the costs are really high

31

00:02:25,920  -->  00:02:31,040
nowadays on the other hand we use new comfort and basic panels and

32

00:02:31,552  -->  00:02:37,440
These are just programmable with TIA portal 13 or newer

33

00:02:38,720  -->  00:02:41,024
That's a con for

34

00:02:41,280  -->  00:02:43,840
Disadvantage in classical world

35

00:02:44,608  -->  00:02:47,424
project generator works with classical

36

00:02:47,936  -->  00:02:51,520
So scripts are working properly on Classical side

37

00:02:52,800  -->  00:02:58,944
sinamics side Wizards and configuration is so much better and faster here

38

00:03:01,504  -->  00:03:03,808
because we already used to

39

00:03:04,576  -->  00:03:10,720
Work with this environments I can remember the settings and menus and wizards

40

00:03:11,744  -->  00:03:16,096
So I can work faster when I switch back to TIA world

41

00:03:17,632  -->  00:03:23,776
and There's a software package sinamics basic and startdrive advanced in New version

42

00:03:24,032  -->  00:03:26,848
TIA portal for 15 and 16

43

00:03:27,872  -->  00:03:34,016
So it's possible to configure your sinamics s120 side on your

44

00:03:35,040  -->  00:03:36,832
TIA portal IDE

45

00:03:37,856  -->  00:03:44,000
But there are some but still there are somethings are missing and the Wizards are terrible right now so

46

00:03:45,024  -->  00:03:48,096
That's why I prefer the use classical way

47

00:03:55,264  -->  00:03:59,104
When programmers should use TIA scout?

48

00:03:59,616  -->  00:04:00,896
What is the most

49

00:04:01,152  -->  00:04:07,296
Program PLC and HMI together with comfort new series panels maybe you should

50

00:04:07,552  -->  00:04:10,112
continiue with this way

51

00:04:10,880  -->  00:04:12,416
classical TIA scout

52

00:04:13,952  -->  00:04:19,327
By the way if your programming several of CPUs and there's a communication between

53

00:04:19,839  -->  00:04:24,191
Simotion at step71500 is always to use

54

00:04:24,703  -->  00:04:29,311
with profinet IO device controllers communication

55

00:04:29,567  -->  00:04:30,335
Then

56

00:04:30,591  -->  00:04:32,639
Maybe you should select you TIA scout

57

00:04:32,895  -->  00:04:35,711
Because it's easy to do that

58

00:04:36,223  -->  00:04:39,039
Otherwise you have to export

59

00:04:39,295  -->  00:04:40,319
Your

60

00:04:40,575  -->  00:04:43,903
Simotion configuration IO device

61

00:04:44,159  -->  00:04:48,255
as GSDML file and you have to import on the other side

62

00:04:48,767  -->  00:04:49,279
and

63

00:04:49,535  -->  00:04:55,423
If you made some changes later on you have to manually update for the TIA

64

00:04:56,191  -->  00:04:59,519
Export and import again. Take some time

65

00:05:00,799  -->  00:05:01,567
This

66

00:05:03,103  -->  00:05:05,407
Integrated programming is a plus

67

00:05:06,175  -->  00:05:08,223
For TIA Scout

68

00:05:10,527  -->  00:05:13,599
Easy to select HMI text from list

69

00:05:13,855  -->  00:05:19,231
You can design Faster your HMI screens and you can work

70

00:05:19,999  -->  00:05:22,815
Simultaneously with simotion CPU

71

00:05:23,583  -->  00:05:24,607
Normally

72

00:05:25,119  -->  00:05:27,423
It programmer should

73

00:05:28,447  -->  00:05:34,591
Make the both of the PLC side and HMI side so that's why you can select

74

00:05:34,847  -->  00:05:35,871
TIA scout

75

00:05:37,407  -->  00:05:38,687
as a minus

76

00:05:39,199  -->  00:05:44,831
You switch TIA or HMI side some modifications can cause

77

00:05:45,087  -->  00:05:46,367
hardware change

78

00:05:47,135  -->  00:05:50,719
That means you have to download your simotion side again

79

00:05:50,975  -->  00:05:53,791
and CPU goes to stop state

80

00:05:54,303  -->  00:05:58,911
So you lose much time specially on low-level CPUs

81

00:06:04,543  -->  00:06:07,871
D410 or D425

82

00:06:08,639  -->  00:06:12,223
This is some kind of a BUG with TIA Scouts

83

00:06:15,807  -->  00:06:20,159
basically you're just opening your project when you double-click

84

00:06:21,183  -->  00:06:26,047
Similar version of the classical scout is opening on new window

85

00:06:27,071  -->  00:06:29,631
That are some functions still missing

86

00:06:30,143  -->  00:06:34,751
Scripts are not working properly yet unfortunately

87

00:06:35,519  -->  00:06:38,591
That's the cons of TIA Scout

88

00:06:43,967  -->  00:06:46,015
Also the TIA portal

89

00:06:46,271  -->  00:06:48,319
Requires more RAM

90

00:06:48,831  -->  00:06:51,391
and more CPU resources

91

00:06:52,415  -->  00:06:54,719
That's why I'm working is slowly

92

00:06:55,743  -->  00:06:58,559
When you compared to classical siemens

93

00:06:58,815  -->  00:07:00,863
Programs and

94

00:07:01,119  -->  00:07:04,191
Like manager and wincc flexible

95

00:07:07,263  -->  00:07:10,591
That's another cons for The TIA Scout

96

00:07:12,895  -->  00:07:19,039
Because on the field working sometimes is really successful you have to manage your time

97

00:07:19,295  -->  00:07:21,087
Properly and wisely

98

00:07:24,415  -->  00:07:25,439
and...

99

00:07:27,231  -->  00:07:31,327
I'm sorry about the TIA portal doesn't help you at this case

100

00:07:32,351  -->  00:07:34,143
You have to use

101

00:07:34,655  -->  00:07:37,983
SSD hard drives with very powerful configuration

102

00:07:38,239  -->  00:07:39,263
Laptop

103

00:07:45,663  -->  00:07:47,199
you need than

104

00:07:47,711  -->  00:07:50,015
utilization of TIA is too high

105

00:07:52,063  -->  00:07:57,183
So you're just click and wait a couple of minutes sometimes during compilation

106

00:07:58,719  -->  00:08:02,559
Online Diagnostic and data transfer a little bit slower

107

00:08:02,815  -->  00:08:05,631
Running compared to classical scout

108

00:08:07,423  -->  00:08:08,447
And

109

00:08:12,287  -->  00:08:13,567
it Is a minus

110

00:08:14,591  -->  00:08:16,383
So next thing is

111

00:08:17,407  -->  00:08:20,991
About sinamics drive site option released for

112

00:08:21,503  -->  00:08:26,111
it is possible configure your drive cliq objects projects on your Hardware

113

00:08:26,879  -->  00:08:31,743
Device and networks on TIA but there are some bugs also

114

00:08:31,999  -->  00:08:35,839
Like Safety integrated functional sometimes with

115

00:08:36,351  -->  00:08:40,703
Different firmware versions if it's not working properly

116

00:08:42,751  -->  00:08:46,591
You just here see the TIA Scout

117

00:08:46,847  -->  00:08:48,895
there are some menus shortened

118

00:08:52,735  -->  00:08:56,063
For some reason

119

00:09:01,439  -->  00:09:05,023
It's your choice but if it's possible I think

120

00:09:05,279  -->  00:09:07,327
i should select and

121

00:09:07,583  -->  00:09:09,631
I prefer to continue with classical world

122

00:09:09,887  -->  00:09:14,239
at the end that is my opinion

123

00:09:16,287  -->  00:09:18,847
Advanced it's up to you

124

00:09:21,663  -->  00:09:27,807
it is short chapter just for your information

125

00:09:28,831  -->  00:09:33,695
I think it's a good way to transfer some knowledge or experience from

126

00:09:35,231  -->  00:09:38,047
One collegue to another college so... See you next time.