1

00:00:00,256  -->  00:00:05,632
Hello again current chapter number is

2

00:00:05,888  -->  00:00:06,912
39

3

00:00:07,168  -->  00:00:13,056
Now we will make a short review of CF cards

4

00:00:13,312  -->  00:00:15,360
Folders and files

5

00:00:16,128  -->  00:00:22,272
I have already inserted a cf cart to my card reader and connected with

6

00:00:22,528  -->  00:00:23,808
via USB

7

00:00:27,392  -->  00:00:32,768
So let's say that are some files and folders here

8

00:00:41,472  -->  00:00:43,264
I will continue

9

00:00:45,312  -->  00:00:49,664
This is the root folder drive letter is "F"

10

00:00:50,688  -->  00:00:55,552
When I right click to CF card properties

11

00:00:55,808  -->  00:01:00,416
This is the Siemens products CF card capacities

12

00:01:00,672  -->  00:01:01,696
1 gigabytes

13

00:01:02,464  -->  00:01:08,608
In file system for new type of simotion CPUs is 

14

00:01:08,864  -->  00:01:11,168
FAT32

15

00:01:14,752  -->  00:01:19,104
The old CF cards for old CPUs were

16

00:01:19,360  -->  00:01:25,504
512 megabytes and file system was fat16

17

00:01:27,808  -->  00:01:29,856
So...

18

00:01:30,368  -->  00:01:34,464
here there is an content dot Exe file

19

00:01:36,000  -->  00:01:39,072
You can see here the

20

00:01:40,096  -->  00:01:42,144
firmware version of

21

00:01:43,936  -->  00:01:48,288
Simotion flash is internally 5.3

22

00:01:48,800  -->  00:01:54,944
The latest one and there are several components with

23

00:01:55,200  -->  00:01:59,552
versions and labels as table

24

00:02:03,648  -->  00:02:04,928
Is this the

25

00:02:05,440  -->  00:02:08,000
Inside this file

26

00:02:09,536  -->  00:02:12,608
So when you connect

27

00:02:13,120  -->  00:02:17,984
sensor module or terminal module

28

00:02:18,752  -->  00:02:20,032
For instance

29

00:02:22,080  -->  00:02:23,360
and

30

00:02:24,640  -->  00:02:26,176
Over drive cliq

31

00:02:27,968  -->  00:02:31,040
current firmware version must be met

32

00:02:31,808  -->  00:02:34,112
For this case 4.8

33

00:02:35,136  -->  00:02:41,280
The system automatically do the necessary firmware upgrade and downgrade procedure

34

00:02:43,328  -->  00:02:45,888
So...

35

00:02:48,448  -->  00:02:54,592
There are some txt files as license with different language

36

00:02:56,640  -->  00:03:00,480
So there's another zip file

37

00:03:00,736  -->  00:03:02,528
Resources OSS

38

00:03:03,808  -->  00:03:05,856
Let's see the readme

39

00:03:06,880  -->  00:03:11,488
siemens 3rd party software disclosure documentary

40

00:03:15,072  -->  00:03:17,120
and There are some information

41

00:03:17,632  -->  00:03:18,912
Components

42

00:03:19,424  -->  00:03:22,240
Used inside the system

43

00:03:23,520  -->  00:03:26,080
7zip is open source

44

00:03:26,848  -->  00:03:32,224
Access database engine is working in firmware kernel

45

00:03:34,016  -->  00:03:38,624
there is a Apache cplusplus XML parts of inside

46

00:03:38,880  -->  00:03:42,464
You can see all of the components is running

47

00:03:43,744  -->  00:03:45,792
As I mentioned before

48

00:03:46,560  -->  00:03:52,704
it Is a linux-based system so that's why there are some gnu components compiler

49

00:03:52,960  -->  00:03:53,984
and

50

00:03:54,496  -->  00:03:56,544
 libraries

51

00:03:56,800  -->  00:04:01,920
JQuery components for web pages

52

00:04:02,176  -->  00:04:08,320
There's a VNC server library and Linux kernel version here you see

53

00:04:10,624  -->  00:04:13,184
Openssl and so on

54

00:04:21,631  -->  00:04:25,983
And other file TOC.txt

55

00:04:34,687  -->  00:04:38,527
so There are some information about macros and bicos

56

00:04:41,343  -->  00:04:43,135
and the last one

57

00:04:43,647  -->  00:04:47,231
This is the valid serial number of CF cards

58

00:04:48,511  -->  00:04:49,791
and

59

00:04:50,047  -->  00:04:55,167
When you want to do firmware upgrade or downgrade

60

00:04:55,935  -->  00:05:01,055
The keys folder is important you don't want to loose your keys

61

00:05:02,847  -->  00:05:06,943
it is Text in Unicode format

62

00:05:07,967  -->  00:05:14,111
When you double-click this file you should see a serial number as

63

00:05:14,367  -->  00:05:17,183
32

64

00:05:17,439  -->  00:05:22,303
Characters as I remember so this is your license

65

00:05:22,559  -->  00:05:27,935
You should back up before doing any operation with your CF cards

66

00:05:28,703  -->  00:05:32,543
so there is an addon folder

67

00:05:32,799  -->  00:05:37,151
Open architecture components will be placed here

68

00:05:39,199  -->  00:05:40,991
For instance sinamics

69

00:05:41,503  -->  00:05:47,647
VibrationX components or there are some other libraries as open architecture pack

70

00:05:49,439  -->  00:05:52,767
For instance servo press

71

00:05:53,023  -->  00:05:56,607
software package will be downloaded here

72

00:05:58,399  -->  00:06:02,751
What are some other files related to sinamics side

73

00:06:05,567  -->  00:06:08,895
So next folder is install folder

74

00:06:10,943  -->  00:06:12,991
can be some logs

75

00:06:19,391  -->  00:06:25,535
OEM folder Is related with special solutions by siemens for customers

76

00:06:29,631  -->  00:06:34,239
The siemens folder separated the two

77

00:06:35,775  -->  00:06:37,567
sinamics side

78

00:06:39,103  -->  00:06:40,383
There are some

79

00:06:40,639  -->  00:06:43,199
.ACX extension

80

00:06:43,455  -->  00:06:46,271
I will try to open it

81

00:06:47,551  -->  00:06:50,623
notepad I see the version

82

00:06:51,135  -->  00:06:52,927
And acknowledge key

83

00:06:53,951  -->  00:06:55,743
It's not relevant

84

00:06:56,767  -->  00:06:58,303
inside the code

85

00:06:58,559  -->  00:07:00,351
There's a cu

86

00:07:02,143  -->  00:07:07,263
I think these are compiled files and downloaded via Scout

87

00:07:08,031  -->  00:07:12,383
so system is running according to these files

88

00:07:14,431  -->  00:07:20,575
There are some UFW extraction or different kind of component

89

00:07:22,111  -->  00:07:27,487
Control unit adapter SMC terminal modules...

90

00:07:29,279  -->  00:07:30,815
And data folder

91

00:07:31,327  -->  00:07:33,119
there are some tables

92

00:07:34,655  -->  00:07:36,959
Or config folder

93

00:07:38,495  -->  00:07:44,639
On the other hand inside the simotion folder you'll see some JAVA archive files

94

00:07:48,991  -->  00:07:52,063
It's will be run by System

95

00:07:52,575  -->  00:07:55,135
And devices XML file

96

00:07:57,439  -->  00:07:59,487
you can see

97

00:08:01,279  -->  00:08:04,863
valid drives for this control unit maybe

98

00:08:06,399  -->  00:08:12,543
sinamics g and s series

99

00:08:12,799  -->  00:08:15,615
in OPCUA related files OPC server

100

00:08:17,663  -->  00:08:19,967
The HMI folder

101

00:08:20,223  -->  00:08:22,015
there are some zip files

102

00:08:22,783  -->  00:08:25,343
For instance webconfig.zip

103

00:08:34,815  -->  00:08:37,887
so you can see here some settings

104

00:08:40,447  -->  00:08:46,591
inside HMI HTML folder webtrace viewer

105

00:08:47,615  -->  00:08:51,711
You can download and install in your computer

106

00:08:56,063  -->  00:09:01,951
There are some some images

107

00:09:02,207  -->  00:09:05,279
Used in web page and web server

108

00:09:05,535  -->  00:09:10,399
scripts working int HTML files

109

00:09:13,727  -->  00:09:19,871
Contact management system styles.css. Styles templates and so on

110

00:09:26,527  -->  00:09:31,903
Last folder name to user inside

111

00:09:32,671  -->  00:09:33,951
there is a ETC route

112

00:09:34,719  -->  00:09:36,767
and sinamics

113

00:09:37,535  -->  00:09:41,887
Code and data runtime directory

114

00:09:42,399  -->  00:09:43,935
Time stamps

115

00:09:45,215  -->  00:09:50,847
Inside the simotion folder that are some user files

116

00:09:51,103  -->  00:09:52,639
in HMI

117

00:09:53,151  -->  00:09:59,295
files Applications Enterprise we have downloaded and

118

00:09:59,551  -->  00:10:02,879
installed to this folder via project generator

119

00:10:04,671  -->  00:10:07,231
These are user designed web pages

120

00:10:10,047  -->  00:10:13,375
Other folder simotion it

121

00:10:16,447  -->  00:10:18,751
There are some libraries

122

00:10:19,519  -->  00:10:21,823
There are some scripts

123

00:10:25,919  -->  00:10:30,015
This folder is related with persistent data

124

00:10:30,271  -->  00:10:36,415
If your create diagnostics it should be stored here in Project or system log

125

00:10:37,439  -->  00:10:40,511
And user files in user log

126

00:10:43,583  -->  00:10:46,655
The other folder is HMI config

127

00:10:47,935  -->  00:10:52,799
there are some configuration files here runtime directory

128

00:10:53,055  -->  00:10:57,663
inside the Upp folder you're going to find units

129

00:10:57,919  -->  00:11:00,479
installed libraries there

130

00:11:01,503  -->  00:11:07,647
and your download of units for instance MCC main unit

131

00:11:11,231  -->  00:11:14,815
By the way these are compiled data

132

00:11:15,583  -->  00:11:18,399
That's why you can't see

133

00:11:19,423  -->  00:11:20,959
The source

134

00:11:25,567  -->  00:11:29,151
Other units For instance ST_DB

135

00:11:29,919  -->  00:11:32,479
its also a compiled unit

136

00:11:37,599  -->  00:11:41,951
you see here some definitions

137

00:11:45,791  -->  00:11:49,631
So these are your project data

138

00:11:50,143  -->  00:11:51,679
User programs

139

00:11:53,215  -->  00:11:57,311
There are some system data blocks

140

00:11:58,079  -->  00:12:02,175
these are your Hardware configuration basically

141

00:12:08,063  -->  00:12:11,391
So there's a configuration folder

142

00:12:12,927  -->  00:12:18,047
Yeah there are some data about technology objects I assume

143

00:12:21,887  -->  00:12:24,959
This is about database

144

00:12:25,215  -->  00:12:28,031
The latest execution system is

145

00:12:30,335  -->  00:12:32,127
So

146

00:12:40,575  -->  00:12:42,367
Options

147

00:12:43,647  -->  00:12:49,791
Export and import unit and

148

00:12:50,303  -->  00:12:53,631
it will be stored as that file to here

149

00:12:56,447  -->  00:13:02,591
and you can download or upload via FTP or VIA website

150

00:13:04,895  -->  00:13:10,271
That means you can create your own recipe system in simotion

151

00:13:10,783  -->  00:13:12,063
By using

152

00:13:12,319  -->  00:13:14,879
System commands and CF cards

153

00:13:16,415  -->  00:13:19,231
The memory is quite good enough

154

00:13:21,791  -->  00:13:25,119
And basically that's it

155

00:13:26,143  -->  00:13:29,215
You can also

156

00:13:29,983  -->  00:13:32,031
Go to with other chapters

157

00:13:32,799  -->  00:13:38,687
FTP server or web server and

158

00:13:39,711  -->  00:13:41,759
we have already

159

00:13:42,783  -->  00:13:45,599
spoken And talked about

160

00:13:46,623  -->  00:13:49,695
The usage of save

161

00:13:50,207  -->  00:13:56,351
retain variables export and Import data set in the other chapters

162

00:13:56,863  -->  00:14:03,007
So about firmware and upgrades and downgrades

163

00:14:04,031  -->  00:14:08,383
I think you should get a back up maybe you just right-click and

164

00:14:08,639  -->  00:14:12,223
Your Cf card to any folder is possible

165

00:14:14,271  -->  00:14:17,855
So if you have some

166

00:14:18,623  -->  00:14:23,231
image Management program like acronis is also possible to take the current

167

00:14:24,255  -->  00:14:27,327
Image of CF cards

168

00:14:28,351  -->  00:14:29,375
And

169

00:14:29,631  -->  00:14:34,751
due to card readers and old types of cards

170

00:14:35,519  -->  00:14:37,823
copy file and folder

171

00:14:38,079  -->  00:14:39,615
Takes sometimes

172

00:14:40,639  -->  00:14:41,919
Long time

173

00:14:44,735  -->  00:14:49,599
all of the files of folders just total size is

174

00:14:49,855  -->  00:14:51,903
Nearly a hundred megabytes

175

00:14:52,415  -->  00:14:55,487
And the rest of the CF CARD is empty

176

00:15:00,351  -->  00:15:02,399
See you next time.