1

00:00:00,256  -->  00:00:01,792
Hello again

2

00:00:02,048  -->  00:00:02,816
Now

3

00:00:03,072  -->  00:00:06,144
current topic and chapter 14

4

00:00:07,936  -->  00:00:11,008
Simotion FTP server and web server

5

00:00:17,408  -->  00:00:23,552
lets take a look first at web server

6

00:00:23,808  -->  00:00:25,088
functionality here First page

7

00:00:31,232  -->  00:00:37,376
At the homepage you'll see here the order number revision number

8

00:00:37,632  -->  00:00:41,216
License serial number of current device

9

00:00:43,264  -->  00:00:47,872
At the device info there are some information

10

00:00:48,384  -->  00:00:51,968
About our technology packages installed

11

00:00:52,224  -->  00:00:56,064
About the MLFB no and serial of the hardware

12

00:00:57,088  -->  00:01:00,160
On the IP config section and tap

13

00:01:00,416  -->  00:01:04,256
you will see here all of the

14

00:01:05,280  -->  00:01:11,424
Current interface IP addresses these are useful information when you are going to

15

00:01:12,704  -->  00:01:17,056
give Service some customer on site

16

00:01:17,568  -->  00:01:21,408
And think about you didn't commissioned machine

17

00:01:24,992  -->  00:01:26,784
in diagnostic tab

18

00:01:27,040  -->  00:01:33,184
That are too many different types at the first one in Diagnostics you see your the memory load

19

00:01:34,720  -->  00:01:37,280
And the current operating States

20

00:01:38,304  -->  00:01:44,448
Number of possible connections to web server and So on

21

00:01:44,704  -->  00:01:47,264
task runtime It's the same table

22

00:01:47,776  -->  00:01:51,872
Almost when you go online and connect with simotion

23

00:01:52,384  -->  00:01:57,248
here the current task state

24

00:01:57,760  -->  00:01:59,040
and task timings

25

00:01:59,808  -->  00:02:04,928
service overview it's almost same table in the simotion Scout

26

00:02:07,744  -->  00:02:09,536
basically Main idea is

27

00:02:10,048  -->  00:02:16,192
When you don't have scout ide we are

28

00:02:18,240  -->  00:02:21,824
You want think about the firmware updates and

29

00:02:22,336  -->  00:02:26,944
You can download the program via the web server is possible

30

00:02:27,712  -->  00:02:31,296
via remote connection or VPN or whatever

31

00:02:33,344  -->  00:02:35,392
So it's very useful

32

00:02:35,904  -->  00:02:38,208
In older versions

33

00:02:38,720  -->  00:02:41,280
For example 4.4

34

00:02:42,048  -->  00:02:48,192
There were no Administration or web server you just entered the password simotion and user name simotion

35

00:02:49,472  -->  00:02:51,008
After that

36

00:02:53,568  -->  00:02:59,712
Need firmware versions you have to call here you're using Administration really do it and

37

00:02:59,968  -->  00:03:01,248
Tips and tricks

38

00:03:05,344  -->  00:03:08,160
So next one is watch table

39

00:03:08,672  -->  00:03:13,024
You can create your own watch tables with

40

00:03:13,792  -->  00:03:16,608
Siemens simotion device variables

41

00:03:18,144  -->  00:03:24,288
it's looks like similar when you're connected via OPC XML client

42

00:03:26,848  -->  00:03:29,408
And next tab device Trace

43

00:03:29,664  -->  00:03:31,968
we tried once to get

44

00:03:32,736  -->  00:03:37,600
extension WTOC files and some data

45

00:03:37,856  -->  00:03:40,672
This is the web based device Trace

46

00:03:41,952  -->  00:03:48,096
So you see here the second one system trace is possible to configure in the webpage

47

00:03:50,912  -->  00:03:54,496
and trace viewer there is a tool

48

00:03:55,776  -->  00:03:58,592
To view your recorded traces

49

00:03:59,872  -->  00:04:01,664
and task trace

50

00:04:04,480  -->  00:04:10,112
You can configure a record data task trace get transferred from Simotion

51

00:04:18,303  -->  00:04:20,863
You'll see here and right click

52

00:04:21,119  -->  00:04:24,191
target device

53

00:04:24,447  -->  00:04:28,543
device diagnostics same thing

54

00:04:37,759  -->  00:04:43,903
General Diagnostic files via diag button

55

00:04:44,159  -->  00:04:49,791
 files recorded in CF card example that you can download after run

56

00:04:50,815  -->  00:04:53,375
With gets all diagnostic files

57

00:04:53,631  -->  00:04:54,655
From here

58

00:04:55,167  -->  00:04:56,959
It's very easy

59

00:05:01,567  -->  00:05:05,407
next page message and log profile

60

00:05:06,687  -->  00:05:11,039
here current diagnostics buffer

61

00:05:12,319  -->  00:05:16,159
Next Step diagnostic buffer of the drive site

62

00:05:16,415  -->  00:05:17,951
Alarms

63

00:05:18,207  -->  00:05:20,767
Technology object alarms

64

00:05:21,023  -->  00:05:22,559
alarms of drive

65

00:05:23,327  -->  00:05:25,119
Alarm buffer

66

00:05:28,447  -->  00:05:31,519
System log file

67

00:05:33,055  -->  00:05:35,871
You can also get from here

68

00:05:36,127  -->  00:05:37,407
System log

69

00:05:37,663  -->  00:05:38,943
It's same thing

70

00:05:41,503  -->  00:05:44,831
ITDIAG LOG

71

00:05:45,087  -->  00:05:46,367
Update log

72

00:05:46,623  -->  00:05:49,183
and user log...

73

00:05:51,999  -->  00:05:55,839
nex page is Machine overview

74

00:05:56,095  -->  00:05:57,887
Module information

75

00:05:59,935  -->  00:06:00,959
So

76

00:06:01,471  -->  00:06:05,823
You'll get some information about current working

77

00:06:06,079  -->  00:06:07,359
Communication lines

78

00:06:07,871  -->  00:06:14,015
If you create a configuration file and download to cf card

79

00:06:14,271  -->  00:06:17,087
after you are able to see here

80

00:06:17,343  -->  00:06:19,903
The model States or IO States

81

00:06:20,927  -->  00:06:22,975
For the topology

82

00:06:24,511  -->  00:06:27,583
There's also some topology table

83

00:06:27,839  -->  00:06:30,399
You receive all of the device

84

00:06:34,239  -->  00:06:35,775
But first

85

00:06:36,031  -->  00:06:37,823
You have to create

86

00:06:38,335  -->  00:06:40,639
in your PC to configuration file

87

00:06:41,407  -->  00:06:44,223
Then upload your machine configuration

88

00:06:44,735  -->  00:06:47,039
and simotion will restarted

89

00:06:47,295  -->  00:06:48,831
Afterwards

90

00:06:51,391  -->  00:06:53,951
Your configuration file

91

00:06:54,975  -->  00:06:56,511
Regenerated

92

00:06:57,023  -->  00:07:00,095
From the semantic Hardware this is another topic

93

00:07:01,119  -->  00:07:03,423
So I don't go into details

94

00:07:04,959  -->  00:07:10,847
In the manage config section that are two tops first one is device updates

95

00:07:11,359  -->  00:07:17,503
You can here select zip file for firmware update or program download

96

00:07:17,759  -->  00:07:21,087
to CPU via webbrowser

97

00:07:23,903  -->  00:07:27,999
You should select the compressed zip file

98

00:07:30,815  -->  00:07:34,911
Or you can get selected data

99

00:07:36,959  -->  00:07:39,263
from the real system

100

00:07:39,519  -->  00:07:40,543
Projects

101

00:07:41,311  -->  00:07:42,591
At this case

102

00:07:43,615  -->  00:07:47,967
There's a progress bar when i hit to get selected data

103

00:07:48,735  -->  00:07:54,879
Device has to be installed

104

00:07:55,903  -->  00:07:57,439
and

105

00:07:57,695  -->  00:08:01,023
It is prepared for us to download

106

00:08:01,279  -->  00:08:03,071
when i click here

107

00:08:04,607  -->  00:08:09,215
And after that you see here are downloaded a zip file

108

00:08:10,239  -->  00:08:16,383
I'm inside that are some files copied here from CF card

109

00:08:16,895  -->  00:08:23,039
Only the project files here is the project as zipped

110

00:08:23,295  -->  00:08:26,111
Is user simotion folder

111

00:08:26,367  -->  00:08:30,463
runtime directory and some txt files

112

00:08:30,975  -->  00:08:34,559
Because we didn't download it the source and project

113

00:08:35,071  -->  00:08:38,143
That's why there's not so many file

114

00:08:39,167  -->  00:08:45,311
And the next thing is restore last update of the present motion devices

115

00:08:45,567  -->  00:08:46,591
Recent

116

00:08:47,359  -->  00:08:52,735
Restorable update data is available yes or no let's say no

117

00:08:52,991  -->  00:08:59,135
That means you have to create some restore point after that you are able to do restoration

118

00:09:01,183  -->  00:09:02,207
Yep

119

00:09:04,511  -->  00:09:09,119
In the next tab simotion IT there are several types

120

00:09:10,143  -->  00:09:11,679
file access

121

00:09:11,935  -->  00:09:17,311
You can arrange or create an alliance for your directories

122

00:09:19,359  -->  00:09:22,431
Or file names you just enter here

123

00:09:24,223  -->  00:09:25,247
Or the delete

124

00:09:33,183  -->  00:09:35,743
Server options

125

00:09:38,047  -->  00:09:39,327
browser protection

126

00:09:39,583  -->  00:09:42,399
symbols and types

127

00:09:43,167  -->  00:09:46,751
Some setting for file extension

128

00:09:47,007  -->  00:09:49,311
Configuration data

129

00:09:49,823  -->  00:09:50,847
consist of

130

00:09:52,127  -->  00:09:53,663
some variables

131

00:09:54,431  -->  00:09:57,503
watch table writable yes

132

00:09:58,271  -->  00:10:01,599
Basic watch table

133

00:10:02,623  -->  00:10:08,767
User and password section is important because you manage your

134

00:10:14,655  -->  00:10:19,775
user administration here Is possible to get file

135

00:10:21,055  -->  00:10:25,919
You can create some user offline then send the file again

136

00:10:27,711  -->  00:10:30,527
or you can here add a user and administration

137

00:10:31,039  -->  00:10:32,575
Or a user

138

00:10:32,831  -->  00:10:35,391
Name password

139

00:10:36,415  -->  00:10:37,951
And

140

00:10:38,463  -->  00:10:41,279
it will be added to the user list

141

00:10:42,047  -->  00:10:44,351
Certificates

142

00:10:46,399  -->  00:10:51,007
You can send or get certificates related to device

143

00:10:52,543  -->  00:10:53,823
web config

144

00:10:55,103  -->  00:11:00,479
You can download or upload entire web config of device

145

00:11:01,759  -->  00:11:05,855
User-defined messages named as alarms

146

00:11:07,135  -->  00:11:11,487
You can send as a XML format

147

00:11:12,511  -->  00:11:14,303
To change the

148

00:11:14,559  -->  00:11:16,607
AlarmS specially

149

00:11:16,863  -->  00:11:19,167
In opc-ua

150

00:11:20,703  -->  00:11:26,079
anyone can read administrator can write the variables

151

00:11:26,335  -->  00:11:30,943
This IP addresses on this port

152

00:11:34,015  -->  00:11:40,159
Next section settings you can set the CPU in RUN and set to STOP

153

00:11:40,415  -->  00:11:44,767
Is also

154

00:11:45,535  -->  00:11:48,863
Must be entered by login as

155

00:11:49,119  -->  00:11:50,399
Administrator

156

00:11:51,167  -->  00:11:52,959
You have to

157

00:11:53,727  -->  00:11:56,287
Use your rights

158

00:11:56,799  -->  00:12:02,943
Requirements are necessary Administration rights because in real working systems

159

00:12:04,223  -->  00:12:10,367
You don't want to interfere or someone unknown connect and stop your system

160

00:12:15,231  -->  00:12:19,327
it could be set system time and

161

00:12:20,607  -->  00:12:22,143
simotion time

162

00:12:23,679  -->  00:12:29,823
and Next section and files here files as list and

163

00:12:30,079  -->  00:12:30,847
folders

164

00:12:31,615  -->  00:12:33,663
Applications

165

00:12:33,919  -->  00:12:40,063
interbranch as you remember we have downloaded some web pages

166

00:12:40,319  -->  00:12:42,111
via FTP server so

167

00:12:43,391  -->  00:12:47,231
you can name and delete some files or just

168

00:12:47,999  -->  00:12:50,303
Copy or remote or

169

00:12:50,815  -->  00:12:51,839
relocate

170

00:12:52,095  -->  00:12:53,631
On the web page

171

00:12:54,399  -->  00:12:57,215
users area

172

00:12:57,471  -->  00:13:00,031
Last time we have already seen

173

00:13:00,799  -->  00:13:04,383
interbranches and some user pages

174

00:13:05,407  -->  00:13:11,551
There's an information Source unit not found of course because we didn't download it

175

00:13:11,807  -->  00:13:13,599
our program

176

00:13:14,367  -->  00:13:17,439
So that's why there's no interconnection

177

00:13:20,767  -->  00:13:26,399
From upper right corner you see the watch

178

00:13:27,679  -->  00:13:31,519
A new pop-up window open as watch table

179

00:13:34,079  -->  00:13:40,223
By the way if you're using different web browsers Chrome is working properly

180

00:13:40,479  -->  00:13:46,623
but with older firmware versions maybe you have to install Firefox or Internet

181

00:13:46,879  -->  00:13:51,231
Explorer because some of the functionality of your not working Chrome

182

00:13:52,255  -->  00:13:53,535
at this case

183

00:13:54,815  -->  00:13:58,399
keep it in your mind

184

00:13:59,167  -->  00:14:02,751
You see here the service overview with me even though

185

00:14:03,007  -->  00:14:05,055
it is basic link

186

00:14:09,151  -->  00:14:10,687
And that's it

187

00:14:13,247  -->  00:14:16,831
I think it's quite covered so much function

188

00:14:20,927  -->  00:14:26,815
next thing How do you use FTP server? before to do that

189

00:14:27,327  -->  00:14:30,911
Let's remember again on the hardware configuration

190

00:14:31,167  -->  00:14:37,311
As default web server is activated but there are some parameters you can adjust

191

00:14:37,567  -->  00:14:39,615
to use the web server

192

00:14:41,407  -->  00:14:44,991
and when you double click on your device you will see

193

00:14:45,247  -->  00:14:50,879
Webserver is activated OPCUA activated FTP and telnet activated

194

00:14:51,135  -->  00:14:53,951
So if you deselect and download

195

00:14:54,463  -->  00:14:57,535
Hardware to your CPU

196

00:14:58,047  -->  00:14:59,583
after that

197

00:15:00,095  -->  00:15:04,447
No one can use the webserver because it's disabled on the device

198

00:15:05,471  -->  00:15:10,591
For some security reasons maybe you should need that

199

00:15:11,615  -->  00:15:13,407
So next

200

00:15:14,687  -->  00:15:18,015
For the web server you can use the

201

00:15:18,271  -->  00:15:20,063
Windows Explorer

202

00:15:20,319  -->  00:15:22,623
Let's see FTP

203

00:15:29,535  -->  00:15:34,655
You have to enter that username and password

204

00:15:35,935  -->  00:15:40,799
It's the meantime I will open another FTP client

205

00:15:43,359  -->  00:15:47,711
Filezilla is commonly used FTP client

206

00:15:48,479  -->  00:15:51,295
Connect to FTP servers

207

00:15:51,551  -->  00:15:54,367
So let's say site manager

208

00:15:56,415  -->  00:15:58,975
Let's say host

209

00:16:01,279  -->  00:16:07,167
This the user is simotion and password is simotion

210

00:16:08,959  -->  00:16:14,079
 I don't remember the port number but let's try this way

211

00:16:16,895  -->  00:16:22,271
server does not support FTP TLS if you continue

212

00:16:23,551  -->  00:16:26,367
Your files you sent me over the internet

213

00:16:26,623  -->  00:16:28,671
421 okay

214

00:16:29,951  -->  00:16:33,023
Check for updates not now

215

00:16:34,303  -->  00:16:37,887
so directory listing is successful

216

00:16:38,655  -->  00:16:44,031
Yeah by the way I am connected on the Windows Explorer

217

00:16:45,567  -->  00:16:48,127
Just see your the

218

00:16:48,383  -->  00:16:51,455
Contents of my CF card actually

219

00:16:52,735  -->  00:16:55,295
there are some folders

220

00:16:56,831  -->  00:16:58,879
Some files

221

00:17:02,463  -->  00:17:06,303
Next time with other applications

222

00:17:06,559  -->  00:17:09,119
Maybe you would use this feature

223

00:17:09,375  -->  00:17:10,399
And because

224

00:17:10,911  -->  00:17:16,543
Sometimes it's not possible to set CPU to stop and power off to

225

00:17:16,799  -->  00:17:22,943
Take the CF card from CPU so if you have to copy download or

226

00:17:23,199  -->  00:17:24,991
upload some file

227

00:17:25,759  -->  00:17:30,623
with This way you can use FTP server functionality

228

00:17:30,879  -->  00:17:33,439
Send files or get files

229

00:17:33,695  -->  00:17:37,791
Of course if it's enabled from the hardware

230

00:17:42,655  -->  00:17:44,447
with this option

231

00:17:44,959  -->  00:17:46,239
Otherwise

232

00:17:46,751  -->  00:17:51,615
It's the service is not started in firmware kernel

233

00:17:52,127  -->  00:17:54,175
So you cannot use

234

00:17:57,247  -->  00:17:59,807
So you have to stop the machine Maybe

235

00:18:03,391  -->  00:18:06,719
there are similar settings in the TIA portal

236

00:18:06,975  -->  00:18:10,559
Device and configuration site so

237

00:18:11,327  -->  00:18:14,655
I can open the project

238

00:18:15,167  -->  00:18:18,239
Show you that

239

00:18:19,263  -->  00:18:21,311
If you are using

240

00:18:21,567  -->  00:18:25,407
Components or CPU

241

00:18:26,175  -->  00:18:32,319
For example siemens 1200 / 1500

242

00:18:32,575  -->  00:18:36,159
TIA portal you already got the information

243

00:18:39,999  -->  00:18:44,095
So I want to delete unused items here

244

00:18:44,863  -->  00:18:46,399
Okay

245

00:18:47,423  -->  00:18:48,703
Let's try

246

00:18:49,727  -->  00:18:51,263
Project opening

247

00:19:00,735  -->  00:19:04,575
So I can go into one level

248

00:19:05,599  -->  00:19:07,135
Inside is folder

249

00:19:07,391  -->  00:19:10,207
From FTP client

250

00:19:11,231  -->  00:19:14,559
I can see select right click download

251

00:19:15,327  -->  00:19:17,887
Or possible to create some

252

00:19:18,399  -->  00:19:19,679
othher directory

253

00:19:19,935  -->  00:19:26,079
It's recomended to use siemens cards with CPU

254

00:19:26,335  -->  00:19:31,711
By the way it's possible to use other CF cards with simotion

255

00:19:32,223  -->  00:19:33,247
SanDisk

256

00:19:33,759  -->  00:19:36,319
4gb 8gb whatever

257

00:19:36,575  -->  00:19:42,719
but siemens doesn't guarantee that your system will work properly because

258

00:19:43,487  -->  00:19:47,839
Read and write feedback times is so much better with

259

00:19:48,351  -->  00:19:50,143
siemens Cf cards

260

00:19:50,399  -->  00:19:55,775
and file system serial numbers in boot sector is more stable

261

00:19:59,359  -->  00:20:04,735
Keep it in your mind if you are using some functions like file read write

262

00:20:06,015  -->  00:20:08,831
in command library

263

00:20:13,183  -->  00:20:13,951
Here

264

00:20:14,207  -->  00:20:15,487
file access

265

00:20:15,999  -->  00:20:21,119
this functions with come with firmware version

266

00:20:21,631  -->  00:20:23,679
4.5 this function will not worked with sandisk

267

00:20:23,935  -->  00:20:27,007
 I remember this function

268

00:20:27,519  -->  00:20:29,823
your program will not work

269

00:20:30,335  -->  00:20:35,711
with another CF card

270

00:20:36,479  -->  00:20:42,111
So your program did not work if you're not using siemens cf cards

271

00:20:43,135  -->  00:20:44,159
deep note!

272

00:20:45,183  -->  00:20:49,535
So you'll see here the network view

273

00:20:50,047  -->  00:20:53,119
Device on network in TIA portal

274

00:20:53,375  -->  00:20:55,679
Let's Double Click

275

00:20:56,191  -->  00:20:56,959
D425

276

00:20:57,727  -->  00:21:00,543
simotion cpu

277

00:21:04,127  -->  00:21:06,431
Under the screen

278

00:21:06,687  -->  00:21:07,967
below

279

00:21:08,735  -->  00:21:10,783
You see your web server

280

00:21:11,039  -->  00:21:13,087
Network protocols

281

00:21:13,343  -->  00:21:15,135
Activate web server

282

00:21:16,159  -->  00:21:19,488
Is the same functionality different

283

00:21:20,000  -->  00:21:23,072
Graphical view for visual view of

284

00:21:23,840  -->  00:21:24,864
The same thing

285

00:21:25,632  -->  00:21:26,912
at the end

286

00:21:27,168  -->  00:21:33,312
When you select it permits access only https

287

00:21:33,568  -->  00:21:35,872
Then that means a secure connection

288

00:21:36,640  -->  00:21:41,504
You have to enter your browser https

289

00:21:45,600  -->  00:21:48,928
Your data will be encrypted

290

00:21:56,096  -->  00:22:01,728
You have to set up this when you are using a UDP communication between CPUs

291

00:22:02,240  -->  00:22:04,800
For some security reasons

292

00:22:05,056  -->  00:22:07,360
with New firmware version

293

00:22:07,616  -->  00:22:13,760
Like put get access similar to simatic CPUs you have to select it in your Hardware to activate it

294

00:22:19,392  -->  00:22:20,928
So...

295

00:22:34,240  -->  00:22:39,360
Also you can use your FTP

296

00:22:39,616  -->  00:22:41,152
in your console

297

00:22:41,408  -->  00:22:47,296
For open as I remember and to the IP address

298

00:22:48,064  -->  00:22:49,856
The connected user

299

00:22:50,624  -->  00:22:53,696
And password logged in

300

00:22:55,488  -->  00:22:57,792
Let's say simotion

301

00:23:04,192  -->  00:23:05,472
Comment okay

302

00:23:07,264  -->  00:23:08,800
That you can use

303

00:23:09,312  -->  00:23:13,664
Your ftp program in your common Console

304

00:23:14,432  -->  00:23:19,040
If you're not downloaded any FTP windows program

305

00:23:21,600  -->  00:23:23,648
It's also another way

306

00:23:29,024  -->  00:23:32,864
So basically that's it we're completed this chapter

307

00:23:33,376  -->  00:23:35,936
Simotion FTP and web server

308

00:23:39,776  -->  00:23:40,800
So...

309

00:23:41,056  -->  00:23:43,616
By the way the other chapter

310

00:23:54,112  -->  00:23:57,184
We're searching and I couldn't see

311

00:23:57,440  -->  00:24:03,584
OPC server objects collection OPC server and

312

00:24:04,352  -->  00:24:08,192
This topic this chapter is related with 14

313

00:24:10,752  -->  00:24:12,800
Keep in your mind. Have a nice day see you !