0
1
00:00:21,630 --> 00:00:23,340
Hello, in this video.
1

2
00:00:23,520 --> 00:00:27,590
We are going to continue to learn ISPsoft interface.
2

3
00:00:27,720 --> 00:00:31,120
Let's create a new file and live it.
3

4
00:00:31,230 --> 00:00:38,010
The name of like this PLC type is ss2 I created a new project a new program.
4

5
00:00:38,010 --> 00:00:41,370
I will create a new and slightly.
5

6
00:00:41,370 --> 00:00:43,110
Task and program name.
6

7
00:00:43,110 --> 00:00:45,950
I will leave it like this and I will say okay.
7

8
00:00:46,130 --> 00:00:53,030
And in here we can come here to say area and transfer sections and upload and download can be usable.
8

9
00:00:53,310 --> 00:00:56,630
And the password things from the system security.
9

10
00:00:56,730 --> 00:01:06,030
Then you can put a password to your APL in here and in here also tools area communications settings
10

11
00:01:06,060 --> 00:01:07,940
that we are using for a while.
11

12
00:01:08,040 --> 00:01:15,120
We need to select our communication driver to communicate with the PLC with the between PLC and station
12

13
00:01:15,120 --> 00:01:20,490
address and etc. from here and tools area change plc type.
13

14
00:01:20,490 --> 00:01:28,140
Now you're selected for example ss2 but you realized your existing actual policy is S22
14

15
00:01:28,140 --> 00:01:37,620
or SA, SV or SS an etc. and you can come here you can select for example AS2 and say yes
15

16
00:01:37,740 --> 00:01:46,020
and say okay and it will change to aS2, can you change your plc type from here in program
16

17
00:01:46,020 --> 00:01:52,350
settings subroutines and projects and the program idea settings then you can put a password or you can
17

18
00:01:52,350 --> 00:02:00,110
change and ideas from here in the option selection when you come here in here General workspace project
18

19
00:02:00,160 --> 00:02:07,920
settings and etc. and also editor's ladder CFC instruction list and structure text and CFC and
19

20
00:02:07,920 --> 00:02:15,030
etc. you can adopt your project settings and workspace area the font types and size and styles and
20

21
00:02:15,060 --> 00:02:24,390
output windows symbol table and also C compiler settings you can adopt them all from here in visitor
21

22
00:02:24,390 --> 00:02:32,910
sections this is also another one important point you can use this visit for example you need to work
22

23
00:02:32,910 --> 00:02:42,600
with the analog input and output you can select AI/AO visa and in here you can select for example
23

24
00:02:43,110 --> 00:02:52,270
your type choice for example select this one upload module from the existing one or enter edit mode.
24

25
00:02:52,500 --> 00:03:01,230
And I will say next for a moment but there is no constancy consistent to see you or module in the reality
25

26
00:03:01,560 --> 00:03:05,090
but you can use this visa.
26

27
00:03:05,220 --> 00:03:13,500
But imagine you need to write the analog input and output ,caught in your PLC project you can come
27

28
00:03:13,500 --> 00:03:23,820
here and you can say okay ocular design of extension modules but this model doesn't support it I will
28

29
00:03:23,820 --> 00:03:33,510
change tools change PLC type I will go back to my ES2 to and I will say okay and I will say yes
29

30
00:03:33,510 --> 00:03:43,490
again visa in here I will say this and in here artilleries stop of setup of extension module will be
30

31
00:03:44,480 --> 00:03:47,710
activated and I will say Okay no zero.
31

32
00:03:47,720 --> 00:03:58,210
The first module is DVP04AD is 2 okay and I will say set up in setup area for example I want to
32

33
00:03:58,210 --> 00:04:00,020
read Channel 1 input.
33

34
00:04:00,130 --> 00:04:01,370
Present value.
34

35
00:04:01,480 --> 00:04:09,830
I will say read registers and read instruction condition LDI m0 is activated.
35

36
00:04:09,910 --> 00:04:18,430
Then you need to read Channel 1 input present value and you need to store this value in the.
36

37
00:04:18,460 --> 00:04:19,570
For example.
37

38
00:04:19,570 --> 00:04:20,740
Five hundred.
38

39
00:04:21,070 --> 00:04:25,610
I will say a list and I will say okay.
39

40
00:04:25,920 --> 00:04:26,280
Okay.
40

41
00:04:27,400 --> 00:04:29,590
Now you can see it in here.
41

42
00:04:29,650 --> 00:04:37,970
When y0 is activated it will read Channel One present value but why zero.
42

43
00:04:38,090 --> 00:04:39,430
We selected wrong.
43

44
00:04:39,450 --> 00:04:41,880
I guess it should be zero.
44

45
00:04:41,880 --> 00:04:45,550
It will read Channel 1 input value.
45

46
00:04:45,640 --> 00:04:48,270
present value from the channel 1.
46

47
00:04:48,270 --> 00:04:50,490
David p 0 for day six.
47

48
00:04:50,580 --> 00:04:57,830
As to module and it will store this present value input.
48

49
00:04:58,170 --> 00:05:01,890
Analog input value in these five hundred.
49

50
00:05:02,190 --> 00:05:07,500
So you can use this visit and also ext module monitor.
50

51
00:05:07,590 --> 00:05:14,310
You can select this module monitor and you can go online to see you and when you connect to your module
51

52
00:05:14,340 --> 00:05:16,970
to your CPU nearby office to see you.
52

53
00:05:17,010 --> 00:05:24,660
You can after set up your settings and communication 1 and ideas and other things and exact error.
53

54
00:05:25,260 --> 00:05:33,600
You can scan these modules and after this visit found your modules you can monitor these modules 
54

55
00:05:33,840 --> 00:05:39,070
easily and effectively and for a moment there is no existing one.
55

56
00:05:39,110 --> 00:05:46,040
In the reality there is no  extension module for our CPU because of this.
56

57
00:05:46,110 --> 00:05:47,910
This is not going to work.
57

58
00:05:48,150 --> 00:05:56,910
I will say stop and I will go back here and here also temperature monitor then you can monitor temperature
58

59
00:05:57,210 --> 00:06:05,910
as 16 or 32 bits and scaling equation that you can put your equation to your here and in here you can
59

60
00:06:05,910 --> 00:06:16,290
see as graphically your temperature and in this area Loadcell module if you say I want to use load
60

61
00:06:16,330 --> 00:06:24,990
cell module in our project you can select an outside module visa and LCsoft is going to open on also
61

62
00:06:24,990 --> 00:06:34,200
you can do a download this LCsoft from Delta web page as freely and in here for example
62

63
00:06:34,200 --> 00:06:41,820
you can adopt your unlock module settings and communication settings in here system settings in here
63

64
00:06:42,120 --> 00:06:50,040
and communications settings also in here parameter settings for example you want to measure gross or
64

65
00:06:50,130 --> 00:06:57,810
net and terror is zero and unit of the measurement and all of them you can adopt in here and calibration
65

66
00:06:57,840 --> 00:07:05,670
that you can in here and the monitor your data killer as kg and Channel 1 way tell you and channel to
66

67
00:07:05,670 --> 00:07:12,210
rate value you can see them all in here and also if there is an error you can see it in here and also
67

68
00:07:12,210 --> 00:07:21,950
status flags in here for uh I'm sure closet for visas that's all and the window cost card or tile work
68

69
00:07:21,980 --> 00:07:28,770
color and tile horizontal and etc. doesn't matter in the help area you can see auxiliary additions
69

70
00:07:28,770 --> 00:07:36,750
for example ocular additions how it helps us protocol settings codes if we go to protocol setting code
70

71
00:07:37,110 --> 00:07:45,570
you can communicate or you can get the result of your communication values for example your data length
71

72
00:07:45,660 --> 00:07:53,390
is eight and parity is often and stop it is to and both rate that you want to communicate speed nineteen
72

73
00:07:53,730 --> 00:07:56,130
at 19200.
73

74
00:07:56,150 --> 00:08:07,250
BP is so right click on I mean right there or just left click to here 009B so the value in D1120
74

75
00:08:07,350 --> 00:08:14,610
Or D 1136 value should be 009B so
75

76
00:08:14,640 --> 00:08:21,840
you can use this small tool but it is really helpful while you are working with the modbus communications
76

77
00:08:22,050 --> 00:08:29,370
but in the next list lessons in the future lessons we will talk about the modbus communication
77

78
00:08:29,400 --> 00:08:37,980
and modbus communication applications at that moment we will use this  tool again so for a moment
78

79
00:08:38,390 --> 00:08:49,580
and in in ISP solve for ISP soft interface Uh we already learn a lot of tools a lot of uh things in
79

80
00:08:49,580 --> 00:08:58,430
here and also one more thing you can add extra networks in here you can use this tool for example
80

81
00:08:58,430 --> 00:09:05,540
normal open contact and you can come here you can edit like this and or for all contact like this and
81

82
00:09:05,540 --> 00:09:12,950
you can add functions with with this when you click here select all types and copy or function blog
82

83
00:09:13,280 --> 00:09:20,630
for example more unique to move away we're ever able to another one data registers for example or
83

84
00:09:20,720 --> 00:09:30,050
value to data registered just click move and say insert and move function will be inserted to here so
84

85
00:09:30,290 --> 00:09:38,510
you can do a small practices you can accompany or you can add a quills like this and below or in here
85

86
00:09:38,660 --> 00:09:47,420
or a little bit for example if you want to write down or if you want to lower you can see an arrow of
86

87
00:09:47,420 --> 00:09:55,400
the coil nearby off the coil arrow now lower and upper and also now lower like this you can use it you
87

88
00:09:55,400 --> 00:10:05,990
can do it practices and with like this you will be an expert and also very very a professional about
88

89
00:10:06,000 --> 00:10:12,920
bias be soft and the Delta pulses after you do a little bit practices but the important thing before
89

90
00:10:12,920 --> 00:10:19,550
you write the Peel programs or course you need to learn your software and software interface to avoid
90

91
00:10:19,640 --> 00:10:25,130
a lose a lot of times while you are writing a course saw for this video I am finished here.
91

92
00:10:25,130 --> 00:10:26,660
See you in the next video.